HMV supply unit
HCS converter
Criterion
Central supply
with HMVxx.x
Parallel opera‐
tion with
HMVxx.xE
(not W0030)
Central
supply
Parallel
operation
High kinetic energies in the
case of mains failure
□
Additionally use HLR braking resistors
Single-phase operation
-
-
□
Only
HCS02
-
■
Recommended
□
Allowed
-
Not allowed
Tab.8-2:
Orientation Guide
8.2.2
HMV Supply Units for HMS/HMD Power Sections
Central Supply HMV
Brief Description
The mains connection "central supply" (individual supply) is the standard type
of connection for HMV. The "central supply" is characterized by one mains
connection (mains circuit breaker, mains transformer, mains filter, mains
choke) for the drive system. Other drive controllers and additional compo‐
nents are connected to the supply unit.
Block Diagram
HMVxx.xE
Components marked with gray background color: Optional, depending
on the application
HMVxx.xR
Mains filter and mains choke; necessary
HMVxx.xR-
W0120
Mains filter, mains choke, external mains contactor; necessary
Fig.8-1:
Central Supply HMV
The "group supply without DC bus connection of the groups" has to be han‐
dled like individual supply for HMV.
Bosch Rexroth AG
DOK-INDRV*-SYSTEM*****-PR06-EN-P
Rexroth IndraDrive Drive Systems with HMV01/02 HMS01/02, HMD01, HCS02/03
96/309
Configuring the Drive System