Converter
Mains chokes
Mains filter
Explanation
HCS03.1E-
W0210
HNK01.1A-A075-E0146
Standard combination for 1 converter
Motor cable length ≤ 75 m
HNL01.1E-0170-
N0146
-
Standard for operating one drive controller without mains filter
HNL01.1E-0170-
N0146
NFD03.1-480-180 Combination for 1 converter
Motor cable length ≤ 5 m
HNL01.1E-0170-
N0146
HNF01.1A-F240-
E0202
Central supply to axis systems
●
Type current HMS ≤ W0150
●
Type current HMD ≤ W0036
●
Sum of type currents ≤ 270
●
2 × 330 nF ≤ C
y
≤ 2 × 600 nF
●
Motor cable length ≤ 240 m (f
s
= 8 kHz)
HNL01.1E-0170-
N0146
HNF01.1A-M900-
E0202
Central supply to axis systems
●
Type current HMS ≤ W0150
●
Type current HMD ≤ W0036
●
Sum of type currents ≤ 270
●
2 × 330 nF ≤ C
y
≤ 2 × 1225 nF
●
Motor cable length ≤ 900 m (f
s
= 8 kHz)
HNL01.1E-0170-
N0146 with
HNL01.1E-3400-
S0202
Customer-side
Standard mains choke connected in series with current-com‐
pensated mains choke to reduce line-frequency leakage cur‐
rents
Tab.8-13:
Selection of Mains Connection HCS03
8.4
Additional Components
8.4.1
Additional Components at the DC Bus
General Information
Converters and supply units basically differ in the following features:
●
Braking resistor integrated
●
Possible connection for external HLR braking resistor
●
Operation of DC bus resistor unit HLB
●
Operation of DC bus capacitor unit HLC
●
Need of HLL chokes for operation
Bosch Rexroth AG
DOK-INDRV*-SYSTEM*****-PR06-EN-P
Rexroth IndraDrive Drive Systems with HMV01/02 HMS01/02, HMD01, HCS02/03
120/309