Form 465, Page 12
Mounting the
Boiler
General Requirements
Before preparing a place for the boiler, check the supporting structure to
ensure it has sufficient load-carrying capacity to support the weight of the
heater.
Model
Net Dry Weight
Operating Weight
lbs
kg
lbs
kg
RAB140
550
250
684
311
RAB235
750
341
938
426
RAB350
1247
566
1562
709
RAB500
1635
742
2074
941
The boiler must be placed on a level, smooth concrete base of sufficient
strength. Sizes 350 and 500 require either 4” x 1/4” flat steel plate or 4”
x 2” x 1/4” angle iron to be cemented in the platform as illustrated. Di-
mensions of the foundation and support strips for Sizes 350 and 500.
RAB 350
RAB 500
inches
mm
inches
mm
A
- Foundation Length
36
914
48-1/2
1232
B
- Foundation Width
33-1/2
851
33-1/2
851
C
- Support Length
28-3/4
730
41-1/4
1048
D
- Support Width
20
508
20
508
Boiler Foundation
Requirements