RFI 150-W-D-DD-H-1 radio modem Operation Manual
Chapter 3 Configuration
MAN0065 Rev 1.7
10
Type the required value and press enter.
(F) Restore Factory Defaults
Sets the radio modem parameters to factory defaults values.
Link Menu Structure
The Link Menu contains the configuration information for the data transmission:
The Lead-In characters that precede a transmission;
The amount of time used to signal that the transmission has stopped.
The menu is shown in Figure 9. Configuration may be required for all the menu elements.
***
Link Control Menu
***
Lead-in Count = 0
Frame Prefill Count
= 1
Data Timeout
= 2
(B)
Lead-in Byte count
(P)
Frame Prefill Count
(T)
Data Timeout
(Esc)
Previous Menu
Enter Choice:
Figure 9: Link Menu
(L) Lead-In Byte Count
This parameter sets the number of lead-in bytes that will be discarded before the real data arrives. The
number of lead-in bytes used must be positive.
The default value is 0
. The following text is displayed:
Enter Lead-in Count (0-1000): 0
(P) Frame Prefill Count
The prefill count is the number of bytes that must be in the serial buffer before the radio will packetise the
data and transmit it. The number must be between 0 and 9 bytes,
the default value is 0
. The following text
is displayed:
Enter Prefill Count (0-9): 0