background image

HORNET PRO 

 

DS-HORNETPRO-4 

With this system, you can pair together any individual transmitter switch with 

any receiver relay switch. Without opening either enclosure: 

1. 

Briefly (less than 1 second) place a magnet next to the receiver in the posi-
tion shown and then remove it. 

2. 

The receiver will buzz once (One buzz means the receiver unit is ready to 

allocate a transmitter button to relay output 1)To select relay output 2, 3 

o 4, briefly place the magnet again so that the Buzzer Buzzes to indicate 
the Relay output 2,3, or 4.  

3. 

Press the switch on the transmitter which you wish to pair 

4. 

The receiver will buzz twice to confirm pairing 

5. 

Repeat for any additional transmitter switches  

 

Advanced operation - Pairing a transmitter button with a magnet 

Pairing a transmitter button using the LEARN switch option  
(12-30Vac-dc Receiver only) 

To pair a new transmitter switch follow this procedure:  
Unscrew the antenna, Open the enclosure, and extract the Circuit-board assembly 

1. 

Briefly press the receiver LEARN switch once 

2. 

The Learn LED will flash once (One flash means the receiver unit is ready to allocate 

a transmitter to relay output 1)  

3. 

To select relay output 2, 3 or 4, briefly press the LEARN switch again and repeat 

until the LED flashes 2, 3 or 4 times. The LED will flash the correct number of times 

to indicate which Relay output is selected.  

4. 

Press the button on the transmitter you want to learn to the chosen relay. 

5. 

The Learn LED will flash to indicate Pairing is complete.     

 
 

Maximum Number of Transmitters to a Receiver 
Each  receiver  has  a  maximum  memory  for  up  to  30  pairings,  these  can  be  from 

the same or any number of transmitters. 
 
 
Erasing Receivers Memory  
1. 

Press and hold the receiver Learn Switch for ~5 seconds.  

2. 

The receiver will sound a long Beep to confirm erased. 

NOTE: You cannot erase individual Tx encoders  

 

LEARN Switch

Summary of Contents for FOBBER-8T6

Page 1: ... to Go Description A versatile general purpose Remote Control System for many different applications Housed in a rugged IP68 weatherproof enclosure The new HORNETPRO system is ide ally suited to any remote switch requirement With upto 4 changeover Relay switch outputs each output can be controlled from any switch on any transmitter Additional transmitters may be added to the system using the same ...

Page 2: ...for further info Range stated is optimum direct line of sight In worst conditions this can be reduced by over 50 Part Number Description Range FOBBER 8T1 1 Sw 200m FOBBER 8T2 2 Sw 200m FOBBER 8T3 3Sw 200m FOBBER 8T4 4 Sw 200m FOBBER 8T6 4 ch 6 Sw 200m FOBBER 8T8 8 Sw 200m FOBBER 8TL1 2 button 1ch ON OFF 200m FOBBER 8TL2 4 button 2ch ON OFF 200m Part Number Description Power Supply HORNETPRO 8R4 4 ...

Page 3: ...Load 1 Open the enclosure by removing fixing screws from the enclosure 2 Remove the antenna and slide out the circuit board 3 Connect the power supply screw terminals 4 Wire your desired connections to the relay contact outputs 5 As supplied the handheld will operate the outputs switch1 to output1 switch2 to output2 etc 6 Set the output functions to latching Momentary Operation COM NO NC Relay Con...

Page 4: ...ff Relay 3 4 operate in the same manor to Transmitter buttons 3 4 12 30V Version LK1 LK2 Link Pins LED s RF Receive RF Transmit LEARN 1 2 3 4 Link Positions Switch relays LK1 LK2 RLY 1 RLY 2 RLY 3 RLY 4 Open Open 1 2 sec Mom 1 2 sec Mom 1 2 sec Mom 1 2 sec Mom Closed Open Mom Mom Latch Latch Open Closed Mom Mom Mom Mom Closed Closed Latch Latch Latch Latch 230Vac Receiver Link Positions Relay Outp...

Page 5: ... Receiver only To pair a new transmitter switch follow this procedure Unscrew the antenna Open the enclosure and extract the Circuit board assembly 1 Briefly press the receiver LEARN switch once 2 The Learn LED will flash once One flash means the receiver unit is ready to allocate a transmitter to relay output 1 3 To select relay output 2 3 or 4 briefly press the LEARN switch again and repeat unti...

Page 6: ...mperature 10 to 50o Celsius The relay contacts in this unit are for functional use only and must not be used for isolation purposes Electrical Characteristics Min Typical Max Units Supply Voltage 2 9 3 3 3 V Supply Current 17 mA Frequency 433 92 869 50 MHz RF Output Power ERP 10 mW RF Bandwidth 60 KHz Electrical Characteristics MIN TYPICAL MAX DIMENSION Supply Voltage for Low Voltage version 11 32...

Page 7: ...HORNET PRO DS HORNETPRO 4 50 00 59 00 46 00 82 00 10 00 All Dimensions in mm 3 x slots 4 5 x 13mm Mechanical Dimensions 76 80 4 20 96 100 Measurements in mm drawing not to scale ...

Page 8: ...RF Solutions Limited et käesolev raadioseadme tüüp määratletud selles dokumendis vastab direktiivi 2014 53 EL nõuetele ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil www rfsolutions co uk FI RF Solutions Limited vakuuttaa että radiolaitetyyppi määratletud selles dokumendis on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen täysimittainen tek...

Reviews: