AS
Mxxxx Series User’s Manual
Asia Pacific | EMEA | Americas
58
Select Data Mode:
Select the data set that you wish to display for the selected Rx Group’s channels.
Four display modes are available:
Max/Min Pwr
Utilisation
Max Pwr (1 chan)
Min Pwr (1 chan)
Since the graph is only able to display approximately 200 data points, each point will normally represent multiple captured level
samples. The selection of the Data Mode controls how the multiple samples are combined to present the plotted data value.
In Max/Min mode, only the maximum and minimum sampled values are used, irrespective of when or how often they occurred in
the selected period. If no value reading (above programmed threshold) has been recorded during the period represented by a
data point then no data will be displayed on the graph.
In Utilisation mode, the displayed data is created from all measurements recorded above the threshold value. If this threshold
value is set too low, all measurements (including site noise) may register a recorded value. As a result, a 100% Utilisation can
be displayed on this graph.
All captured level samples are included in the associated data file, in CSV format, which may be downloaded and processed
independently (i.e. using other software) if desired.
Note:
During calculations, the processing of all of the recorded data to create the graph may result in delays to the display
of the data. If a significant amount of data has been logged, displaying periods back in time may also result in delays
while this data is retrieved from memory,
processed, and then sent to the viewer’s computer.
Display:
Clicking the Display button starts the collation of data that meets the selected criteria. Once the data is processed and the
updated chart created, the screen will refresh. This may take a period of time depending on the number of data values that
have been stored that meet the selected criteria.
Note:
Only channels that have a frequency configured, and which have been enabled will be displayed.