AS
Mxxxx Series User’s Manual
Asia Pacific | EMEA | Americas
94
10.37 Configuration
– Alarm Settings - Tx Port 1
Each of the Tx port (Groups) channel alarms, 1 through to 4 is configurable as illustrated in this Tx Port 1 Alarms page.
Min & Max Power:
Sets the power level limits for alarming of the monitored Tx channels. A signal detected outside these limits will result in an alarm.
Max VSWR:
Sets the VSWR alarm limit.
ALM O/P:
The Alarm Output that thi
s channel’s Min. Pwr or Max. Pwr alarm has been assigned to.
Note:
This is configured in the Configuration
– Alarm Settings – System or Configuration – Alarm Modules screens as required.
Note:
For any text field, the allowable limits for that field (Model dependent) are displayed when the cursor is hovered over it.
Note:
Alarms will only be raised for signals where the Forward Power level exceeds the Threshold Power set on the
Channel Configuration pages.