Defaults:
Clicking this button enters the factory default values for the Channel alarm settings, which are:
Min Power
+42 dBm
Max Power
+49 dBm
Max Ins Loss
1.0 dB
Max VSWR
1.50:1
Discard Changes:
Click this button to restore the values to those present when the page was last re-displayed.
Note that if invalid values are being displayed after an Apply attempt, these values may not match the current system
configuration. In this case, just select the relevant Configuration/Alarms/Tx Port menu item again to re-display the current
configuration.
Apply:
This will attempt to save and activate the values entered. If any out of range values are present, nothing will be saved and the
problem settings will be highlighted with a red background.
Note:
Whenever programming changes are applied, the alarm status for affected channels is re-initialized.