1
+
+
+
+
+
+
+
+
SW3 - SW7 Center Frequency
SW1 - SW2 Shift Down
R23
TP2 (-)
TP4 (+)
SW8 - SW9 Shift Up
Figure 22-5. Controls and Indicators, RFL 9780/85 Transmitter Module (106505)
1. Power down.
2. Check the Transmitter module output level by placing the module on an Extender Card
(RFL P/N 9547-1870). Low power is keyed either with the reserve keying input or by setting
the AM Logic Board Switches SW1-3 and SW1-4 to OFF, and placing the toggle switch on the
AM Logic Board to the UP position.
a. Power up.
b. Connect an oscilloscope
to TP4 (+) and TP2 (-).
c. Observe a 1.9V p-p undistorted waveform while transmitting low power 5 (10) watts. If
necessary, adjust R23 to attain the proper level. A 6V p-p undistorted sine wave should
be observed while transmitting high power 50(100) watts.
d. Power down and reinstall the transmitter module in the 9785 chassis.
e. Power up.
3. Open the front door on the 9508 RF Chassis 50 watt unit as shown below.
Location of 50W
Power Amp Module
Figure 22-6. Location of 50W Power Amplifier
RFL 9785
RFL Electronics Inc
.
March 1, 2013
22-
5
(973) 334-3100