12.2
SPECIFICATIONS
As of the date this manual was published, the following specifications apply to all RFL 9785 Receiver
Detector modules, except where indicated. Because all RFL products undergo constant refinement and
improvement, these specifications are subject to change without notice.
Narrow-Band Filter:
Center Frequency: 24 Khz
Bandwidth:
106515-6:
500Hz
106515-7:
1000Hz
106515-8
1500Hz
Level Indicator:
Span:
±
10 dB
Reference: Typically set to read 0 dB when transmitting a 1W signal from the far end.
Accuracy:
±
5% FS nominal
External Meter Output:
Span:
±
10 dB
Reference: Typically set to read 0 dB when transmitting a 1W signal from the far end.
When configured for
±
1V: Span mapped from +1.00 to –1.00 Vdc.
When configured for 0 to -100
μ
A: Span mapped from 0 to -100
μ
A.
When configured for 0 to -5V: Span mapped from 0 to -5 Vdc into a 5K Ohm load.
Note: External meter outputs are referenced to logic common.
Carrier Detect:
Threshold: -15 dB to +5 dB.
RFL 9785
RFL Electronics Inc.
July 7, 2006
12-2
(973) 334-3100