14.5
VIEWING THE VALUES DISPLAY
To view the current status of the RFL 9785 values display, enter the “V” command.
9785>V
[ENTER]
The “V” command tells the RFL 9785 to send a copy of the values display to your terminal. This
display is for viewing only and cannot be changed by the user. A typical values display is shown in
Figure 14-4.
# ALARM
STATUS
011 Tx Fail #1
Inactive
015 Power Fail #1
Inactive
016 Power Fail #2
Inactive
019 Checkback Fail
Active
# SIGNAL
STATUS
039 Reserve Key
Inactive
040 Remote Initiate
Inactive
041 Start
Inactive
042 Stop
Inactive
043 Block Output
Inactive
044 IRIG-B Status
Unlocked
100 RxCh1 Level
<-10dB
102 TxCh1 PWR(50ohm)
0.4 Watts
104 TxCh1 Actual PWR
0.4 Watts
106 TxCh1 REFL_PWR
0.6%
9785>
Figure 14-4. Typical values display for 9785 operating mode
The values display shows the parameter number for each alarm and signal, a brief description of its
meaning, and its status. Full descriptions of alarms and signals are as follows:
011 – Tx Fail #1
This indicates that transmitter channel #1 has failed.
015 – Power Fail #1
This indicates that a problem has been detected with power supply #1.
In a single supply system, this is the only supply.
016 – Power Fail #2
This indicates that a problem has been detected with power supply #2.
This is only applicable in dual supply systems.
019 – Checkback Fail
This indicates that the Checkback test has failed.