Page 72 of 90
CCT24
Figure 5.6.2.8
Figure 5.6.2.8 shows the first
I/O Setup
tab contents, corresponding to Bank 6 GPIO parameters. This tab
allows the direction of the GPIO ports to be set both for active and sleep modes, and in the case of GPIO
outputs, the initial power up states and sleep mode states to be set. When GPIO ports 0 - 3 are config-
ured as inputs, event interrupts can be set for them with check boxes. The type of interrupt trigger is
selected from the drop-down boxes to the right of the check boxes. GPIO alternate function, periodic I/O
reporting, reporting interval and enable/disable sleep I/O states can also be specified under this tab.
Figure 5.6.2.9
Figure 5.6.2.9 shows the second
I/O Setup
tab contents, corresponding to Bank 6 ADC input and PWM
output parameters. The ADC sampling interval, high and low thresholds for event reporting and event
reporting triggers on each ADC channel can be set, along with the start-up output values for each PWM
(DAC) channel. The event reporting predelay and repeat count parameters can also be set from this tab.