HN-1010/1510
Restart
The Restart button on the Wizard causes the program to start the radio search and
parameter load process again without shutting the program down. This is particularly
useful when USB-to-RS-232 adapters are used that prevent the Wizard from detecting
that a radio has been disconnected from the computer running the Wizard. If a radio is
disconnected from the computer and the Wizard does not detect it, the Restart button
should be clicked when it or another radio is connected. Note that clicking the Restart
button will not change the parameter values stored for use by the Recover button.
Saving Configurations
Configuration settings that have been applied from the Wizard can be saved for future
use. The Wizard prompts to save changes on initial boot-up, after changes have been
applied and on exiting the Wizard if the changes have not previously been saved. The
default filename for the configuration settings is “hn_xxxxxx.cfg” where xxxxxx is
the serial number of the radio in the HopNet (This serial number is also on the outside
of the radio). To save a configuration under another filename, simply enter the
desired filename in the dialog box. Once a configuration has been saved, it can be
used to set up additional HopNet radios with the same configuration by clicking on
the Load command on the File menu. You will be prompted for a filename to load.
Loading the file will load the parameters into the Wizard program but will not
program the settings into the HopNet radio until the Apply Settings button is clicked.
©