HN-1010/1510
Set Range Optimization
This command applies an adjustment factor to the over-the-air timing of remotes to
compensate for the effects of propagation delay at long ranges. The default setting of
00H
is suitable for ranges of 0 to 0.8 miles (1287 m), with optimal performance at 0.1
miles (162m). Each increment of this parameter adds 0.1 miles (162 m) to the
working range. Thus the optimal and max ranges are determined by:
optimal = 0.1mi + 0.1mi x
dx
= 0.17km + 0.17km x
dx
max = 0.8mi + 0.1mi x
dx =
1.33km = 0.17km x
dx
The following table presents various values of dx and the associated optimal and max
ranges.
dx
setting
range:
min
optimal
max
00H 0mi/0km
0.1mi/0.2km
0.8mi/1.3km
01H 0mi/0km
0.2mi/0.3km
0.9mi/1.5km
04H 0mi/0km
0.5mi/0.8km
1.2
mi/2.0km
06H 0.1mi/0.2km
0.7mi/1.2km 1.4mi/2.3km
09H 0.4mi/0.7km
1.0mi/1.6km 1.8
mi/3.0km
13H 1.4mi/2.3km
2.0mi/3.3km 2.8mi/4.7km
31H 4.4mi/7.3km
5.0mi/8.3km 5.8
mi/9.7km
45H 6.4mi/10.7km
7.0mi/11.7km 7.8mi/13.0km
64H 9.4mi/15.7km
10.0mi/16.7km
10.8mi/18.0km
C8H 9.4mi/32.3km
20.0mi/33.3km
20.8mi/34.7km
FAH 4.4mi/40.7km
25.0mi/41.7km
25.8mi/43.0km
Optimal 'dx' setting for various distances.
©