602400011500
Revision C
Page
20
of
24
9
SPECIFICATIONS
Model
GENERAL
APD20
‐
D
APD22
‐
D
APD70
‐
D
APD72
‐
D
Output
Flow,
Minimum,
Nlm
(SCFM)
5.65
(0.2)
4.8
(0.17)
19.8
(0.7)
16.4
(0.58)
Max
System
Volume,
liters
(ft
3
),
@
34.5
kPa
(5
psig)
3500
(123)
1
3000
(106)
1
16500
(582)
1
13500
(477)
1
Output
Dew
Point,
Minimum,
Celsius
(Fahrenheit)
Ambient
dew
points
<=
10°
(50°):
‐
40°
(
‐
40°)
dew
point
Ambient
dew
points
>
10°
(50°):
50°
(72°)
dew
point
reduction
Operational
Pressure,
psig
(kPa)
Firmware
configurable
from
1
‐
10
(6.9
‐
68.9)
Pressure
Deadband,
psig
(kPa)
Firmware
configurable
from
2
‐
9
(13.8
‐
62.1)
Ambient
Operational
Temperature
Range
0
‐
40°C
(32
‐
104°F)
2
Ambient
Operational
Humidity
Range
5
‐
85%
relative,
non
‐
condensing
(maximum
absolute
humidity
=
25
g/m
3
)
2
Operational
Noise,
dBA
@
1
meter,
Standby
0
Operational
Noise,
dBA
@
1
meter,
Active
60
66
Output
Pressure
Safety
Relief
Fixed
at
15
psig
(103.4
kPa)
Output
Fitting
Type
Quick
‐
Connect,
3/8"
OD
Plastic
Tube
3
Maximum
Continuous
Operation,
Active
4
Hours
ELECTRICAL
Operating
Voltage,
AC
120V
+/
‐
10%
230V
+/
‐
10%
4
120V
+/
‐
10%
230V
+/
‐
10%
4
Source
Frequency,
Hz,
Nominal
(Range)
60Hz
(47
‐
63Hz)
50Hz
(47
‐
63Hz)
60Hz
(47
‐
63Hz)
50Hz
(47
‐
63Hz)
Max.
Standby
Current,
Amps
0.5
Max.
Active
Current,
Amps
3
2
5
4
Max.
Active
Power
Consumption,
Watts
320
280
500
420
Max.
Active
Power
Consumption,
Volt
‐
Amps
380
290
520
440
Power
Factor
Correction,
typical
0.8
Electrical
Feed
Circuit
Configuration
Single
Phase,
3
‐
Conductor
(Phase/Neutral/Ground)
4
Electrical
Feed
Circuit
Size
Recommendation
15
Amps
5
Electrical
Inlet
Connector
IEC
320
Type
C14
ALARMS
Alarm
Configuration
1
Form
C
relay
contacts,
screw
terminal
connector
Alarm
Contact
Rating,
Maximum
30VDC,
1A
Low
Pressure
Alarm
(Standard
on
all
units)
Standard
configurations:
Fixed
at
0.5
psi
(3.4
kPa)
below
lower
operational
pressure
Low
Pressure
configurations:
Fixed
at
0.25
psig
(1.7
kPa)
SIZE
AND
WEIGHT
Dimensions,
H
x
W
x
D,
inches
(mm)
9.5
x
13.5
x
9.5
(242
x
343
x
242)
Net
Weight,
pounds
(kilograms)
25
(11.4)
30
(13.6)
ENVIRONMENTAL
Max.
Operational
Altitude
@
5
psig,
feet
(meters)
6,500
(1,930)
6,000
(1,830)
12,400
(3,780)
11,500
(3,500)
Max.
Operational
Altitude
@
10
psig,
feet
(meters)
5,000
(1,525)
4,500
(1,370)
10,900
(3,325)
9,500
(2,900)
Derating
per
1000ft
(305m)
above
MSL,
CFM
(lm)
0.024
(0.68)
0.022
(0.62)
0.07
(1.98)
0.06
(1.70)
Options:
(Field
Configurable)
Low
Pressure
Operation
Software
configurable
from
1
‐
2.5
psig
(6.9
‐
13.8
kPa)
in
0.5
psig
(3.4
kPa)
increments
6
High
Pressure
Alarm
Software
configurable
from
3
‐
11
psig
(20.7
‐
75.9
kPa)
in
1
psig
(6.9
kPa)
increments
Humidity
Alarm
Software
configurable
from
20
‐
50%
RH
in
10%
RH
increments
Run
Time
Alarm
Software
configurable
from
10
minutes
to
4
hours
in
10
minute
increments
System
Purge
Software
configurable
from
2
‐
10
days
in
2
day
increments
Compliance
CE
(EMC,
MD,
PED,
RoHS)
IEC
60529
‐
IP20
NOTES:
1)
All
specifications
at
23°C
(73
F)
and
50%
Relative
Humidity
at
mean
sea
level
(MSL)
unless
otherwise
noted.
2)
For
indoor
use
only.
IEC
60721
‐
3
‐
3
Class
3k3
(temperature
‐
controlled
enclosed
locations,
humidity
not
controlled),
Humidity:
25
g/m3
Absolute
Humidity
@
85%
RH
=
29.4°C,
40°C
@
25
g/m3
Absolute
Humidity
=
48.8%
RH.
3)
Tubing
used
must
be
polyurethane
(durometer
95A),
polyethylene
(durometer
44D),
or
nylon
(durometer
50D).
4)
Voltage
source
per
IEC
60038
(1/N/PE)
***Not
for
use
with
North
American
240VAC
service***
5)
Electrical
supply
circuit
must
remain
within
operating
voltage
specifications
at
all
times.
6)
Lower
Operational
Pressure
fixed
at
0.5
psig
(3.4
kPa),
Low
Pressure
alarm
fixed
at
0.25
psig
(1.7
kPa).