Radio Frequency Systems
BD4200W Series Air Dryer User’s Guide
Page 83 of 114
100518835 - Rev. B
9.16.7
Turn Outlet Pressure
Regulator knob clockwise
until Outlet Pressure
(
OUTLET
) reading raises to
the reading recorded in step
9.16.8
Push knob in to lock.
9.16.9
Reinstall the Front Panel (section 8.10 ).
If you are unable to create a Low Outlet Pressure Alarm as described, see section
13.8 for troubleshooting information.
9.17 Testing Air Fittings & Hoses for Leaks
NOTE:
This is a general procedure that can be applied to any fitting or hose that
has air pressure in it.
DO NOT SOAP TEST THE HUMIDITY SENSOR
FITTING. DAMAGE TO THE SENSOR MAY OCCUR.
With Compressor NOT running:
9.17.1
Listen for any ‘hissing’ sounds which may indicate a fitting or hose air
leak.
With Compressor running:
9.17.2
Use a 1-inch paint brush to dab soapy water on the air fitting or hose
connection to be tested.