Radio Frequency Systems
BD4200W Series Air Dryer User’s Guide
Page 11 of 114
100518835 - Rev. B
5.5 Dryer Function Overview
#
Component
Description
1
Compressor
Compresses drawn in ambient air.
2
Precooler
Cools compressed air prior to drying function.
3
Unloader Valve
Relieves excess Compressor head pressure.
4
Heatless Dryer
Removes moisture from compressed air.
5
Capacity Control Valve
Regulates System Pressure (50 PSI/345 KPa) and
prevents air from bleeding back through the
Heatless Dryer.
6
Air Tank
Stores dry compressed air.
7
Static Pressure Regulator Regulates the Static Pressure (20 PSI/138 KPa)
and maintains constant pressure on the Combo
Block for accurate Flow measuring.
8
Combo Block
Measures the Flow of compressed air and houses
the Humitter.
9
Outlet Pressure Regulator Regulates the Outlet Pressure.
10 Pressure Outlet
Outputs the pressure set by the Outlet Pressure
Regulator.