BD4200W Series Air Dryer User’s Guide
Page 110 of 114
100518835 - Rev. B
14.2 Operational Limits and Defaults
14.2.1
System Adjustments
14.2.2
Alarm Thresholds
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
Shutdown
High Humidity Alarm
3
15
10
%
YES
High Outlet Pressure
Alarm
0.40/2.8
20.00/138
20.00/138
PSI/KPa
Low Outlet Pressure
Alarm
0.30/2
19.90/137
0.30/2
PSI/KPa
High Flow Rate Alarm
0
4200/119
2600/74
SCFD/SCMD
Compressor Last Run
Time Alarm
0.00
10.00
4.00
Minutes
High Duty Cycle Alarm
0
99
70
%
Compressor Total Run
Time Alarm
8000
Hours
High Cabinet
Temperature Alarm
115/46
Deg F/Deg C
Shutdown
at
120
°F/50
°C
14.2.3
System Operations
Description
ON Value
OFF Value
Default
Value
Unit of
Measurement
Compressor
25/172
50/345
PSI/KPa
Fan
ON
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
System Pressure
50/345
PSI/KPa
Static Pressure
20/138
PSI/KPa
Outlet Pressure
(LP UNITS)
5.00/35
(0.30/2.0)
20.00/138
(10.00/69)
PSI/KPa
Alarm Delay
OFF
ON
ON
Start Up Delay
0
10
0
Seconds