8.4.6.3
Compressor Run Time Screen
LAST
– How many minutes the Compressor ran during the last Air Tank
pressurization cycle.
TOTAL
– How many hours the Compressor has run since the last
Compressor Total Time Reset.
8.4.6.4
Unit in Standby Screen
Occurs when the dryer is connected to a Cycle Kit and has been switched
to Standby Mode.
8.5 Identifying Dryer Alarms
8.5.1
High Cabinet Temperature Alarm -
Occurs when the temperature in the dryer cabinet (
CAB TEMP
) rises above
115°F for more than one (1) minute. If the temperature rises above 120°F
for more than one (1) minute, the air dryer will go into S
HUTDOWN
mode
to protect against damage due to overheating.