8.12 Depressurizing the Dryer
8.12.1
Remove the Front Panel (section 8.10 ).
8.12.2
Pull the ring handle on the
Safety Relief Valve until all
air pressure is released.
NOTE
: To prevent pressure
from building back up, power
the dryer
OFF
(section 8.3 ).
8.12.3
Reinstall the Front Panel (section 8.10 ).
8.13 Connecting to Common Alarm Socket
8.13.1
Insert the included Alarm
Connector into either of the
two (2) Alarm Ports.
8.13.2
Wire an external alarm
wire pair to the Alarm
Connector as required:
Common
and
N.C.
for
OPEN ON ALARM
operation.
Common
and
N.O.
for
CLOSE ON ALARM operation.