Radio Frequency Systems
BD4200W Series Air Dryer User’s Guide
Page 71 of 114
100518835 - Rev. B
9.6.5
Use a Voltmeter to measure
across the AC terminals.
The voltage should measure:
110 - 125 VAC
for the
BD4200W & BD4200WLP
models.
220 - 230 VAC
for the BD4202W & BD4202WLP models.
9.6.6
Use a Voltmeter to measure across the DC terminals.
The voltage should
measure
0 VDC
.
9.6.7
Reinstall the Top Cover (section 8.11 ).
If any of the voltage measurements are different than indicated above, the Solid
State Relay is defective and should be replaced. See sections 11.1 for part detail
and 0for ordering information.
9.7 Testing Consistent Heatless Dryer Cycling
9.7.1
Remove the Front Panel (section 8.10 ).
With the Compressor running
:
9.7.2
Disconnect the purge tubes
from the Heatless Dryer.