Radio Frequency Systems
BD4200W Series Air Dryer User’s Guide
Page 73 of 114
100518835 - Rev. B
9.8.3
Place your hand beneath the
Unloader Valve fitting to feel
for air flow.
Air should
NOT
flow from
this fitting continuously. Air
should only be released in a
short burst when the
Compressor shuts off.
9.8.4
Re-connect the unloader
tube to the Unloader Valve.
9.8.5
Reinstall the Front Panel
(section 8.10 ).
If air flows from this valve continuously the Unloader Valve is defective and
should be replaced. See sections 11.4 for part detail and 0for ordering
information.
9.9 Measuring Heatless Dryer Solenoid Voltage
9.9.1
Remove the Front Panel (section 8.10 ).
With the Compressor running
: