9.13 Testing Compressor Last Run Time Alarm
NOTE:
For this test, allow the Display Screen to cycle through the information
screens.
9.13.1
Remove the Front Panel (section 8.10 ).
9.13.2
Start timing when the Compressor turns on.
9.13.3
Pull the ring handle on the
Safety Relief Valve (when
necessary) to keep the Tank
Pressure (
TANK
) from
reaching
50 PSI/345 KPa
.
This prevents the Compressor
from shutting down.
When the Compressor runs
for 4:00 minutes (unless
adjusted to a different
threshold by the user), a
Compressor Last Run Time
Alarm should appear on the
System Screen.
9.13.4
Press the
RESET Button
to clear the alarm.
9.13.5
Reinstall the Front Panel (section 8.10 ).
If you are unable to create a Compressor Last Run Time alarm as described, see
section 13.18 for troubleshooting information.