NOTE:
If the Humitter is disconnected from the Control Board,
**%
will appear
on the Humidity reading and after 5 minutes the unit will Shutdown. This is to
allow for troubleshooting.
If you are unable to create a Humidity / Shutdown alarm as described, see section
13.11 for troubleshooting information.
9.15 Testing High Outlet Pressure Alarm
9.15.1
Make a note of the current
Outlet Pressure (
OUTLET
)
reading.
9.15.2
Remove the Front Panel
(section 8.10 ).
With Compressor running:
9.15.3
Pull the Outlet Pressure
Regulator knob out.
9.15.4
Turn knob clockwise until
Outlet Pressure (
OUTLET
)
reading climbs over the alarm
threshold. (section 8.8.5 )