9.16 Testing Low Outlet Pressure Alarm
9.16.1
Make a note of the current
Outlet Pressure (
OUTLET
)
reading.
9.16.2
Remove the Front Panel
(section 8.10 ).
With Compressor running:
9.16.3
Pull the Outlet Pressure
Regulator knob out.
9.16.4
Turn knob counter-
clockwise until Outlet
Pressure (
OUTLET
) reading
drops below the alarm
threshold. (section 8.8.7 )
9.16.5
After one (1) minute,
verify that a Low Outlet
Pressure Alarm appears on
the display.
9.16.6
Press the
RESET Button
to clear the alarm.