Installation Instruction 

APT1-1 

 

Antenna Tilt Adjustment Tool 

CELaligner

®

 

 

 
 
 
 

 

April 7, 2006            V800                           Vers 1.1 

Radio Frequency Systems 

Please visit us on the internet at http://www.rfsworld.com 

T h e   C l e a r   C h o i c e   i n   W i r e l e s s

T M

 

 

Vertical Calibration 

 

 

Step 1: Press the aligning rod (A) against a perfectly vertical wall 
Step 2: Follow normal aligning procedure until the bubble of the spirit level is centered. 
Step 3: The scale should now be pointing at zero degrees. 

 

Horizontal Calibration 

 

 

 
 
Step 4: Place the aligning rod (A) against a perfectly horizontal plane. 
Step 5: Follow normal aligning procedure until the bubble of the spirit level (B) is centred. 
Step 6: The scale (C) should now be pointing at 90 degrees.    
Step 7: If the statements in step 3 and 6 are not true then the CELaligner

®

 is out of order and should not 

be used. 
 

The CELaligner

®

 should be calibrated once every 12 months.

 

 

 