RFS INSTALLATION GUIDELINES
HYBRIFLEX
®
CABLE|603400210500|September 2020
Visit
for the most current product specifications
Page 12 of 43
HYBRIFLEX cable is supplied in specific cut lengths with fully terminated and polished factory connectors.
Short lengths of small HYBRIFLEX can be hoisted manually, otherwise
a winch is recommended. Provide a pulley high enough on the tower
to enable the HYBRIFLEX line to be raised sufficiently.
Attach a hoisting grip
(do not use a closed lacing style)
using tie back
rope or additional electrical tape if needed to prevent any stress or
force to fiber and electrical wire. When using pre-installed hoisting
grips, simply adjust it to the desired section of the cable and clamp it
or use heavy duty tape to secure it.
For every long vertical run of cable, additional hoisting grips should be
attached at 50-60m intervals.
Add the hoist line to the hoisting grip or rope sling; protect the
HYBRIFLEX against shackles.
Keep slack in the cable between the hoisting grips in case more than
one is needed. Ensure that the slack is maintained during hoisting.
Hoist the cable slowly.
Rotation of the reel must be slow to prevent buckling of the cable.
When unspooling, keep the reel secure so that it does not accidentally
roll over the unprotected components.
If it is necessary to drag the cable over sharp edges of buildings or
tower members, protective measures must be taken.
Careless handling can damage the cable jacket eventually causing
damage to fiber end face which may render the entire HYBRIFLEX line
length useless.
If the cable is hoisted inside the tower, feed it into the tower base and
keep its top off the tower steel work. Please refer to the Monopole
installation section of this document.
Caution!
The protective sleeve should not be removed until
installation is complete.
Hoisting Grips: 1 for every 100ft of vertical run. For heavier runs, such
as 1-
5/8” 4
AWG, use 2 hoisting grips for every 200ft vertical run.
Hoisting Grip
Always secured
with electrical
tape or tie wrap
before applying
tension
Protective
sock
Do not Hoist
without Sock
Minimum
18.12 FT