RFS INSTALLATION GUIDELINES
HYBRIFLEX
®
CABLE|603400210500|September 2020
Visit
for the most current product specifications
Page 19 of 43
Note: If the tool has been started to cut in a spiral, the tool will move continuously by itself in the same
direction. If the marked area is reached, this movement must be stopped by pushing carefully in the opposite
direction. To develop the proper technique, we recommend testing on a part of cable, which is not needed for
the installation. If this process is not easy enough or not acceptable, a clamp (e.g. RSB-Clip) may be placed on
the mark. This clamp will then stop the movement of the tool in the final position [see pictures 2-4].
Put the body of the grounding kit very carefully around the cable, to prevent damaging the outer conductor,
and then carefully tighten the nuts.
Finally use the supplied sealing materials as described in the grounding kits
installation instruction to perform a proper sealing of the complete kit.
For example, GKFORM series, p
lace the remaining third 50 mm (2”) piece of
butyl mastic carefully over the ground wire. (as shown in Diagram 5)
We recommend bending it with overlapping on both sides when placing over
the ground wire. Afterwards mold it in a straight line to the coaxial cable to avoid holes where water could
enter [see Diagram 5].
Special care must also be taken to form
tile-like overlaps when wrapping the tape
layers, i.e. start from the bottom and end
at the top.