RFS INSTALLATION GUIDELINES
HYBRIFLEX
®
CABLE|603400210500|September 2020
Visit
for the most current product specifications
Page 28 of 43
LC connector inspection
1.
Inspect the LC fiber end-face using approved test equipment probe and the appropriate LC fiber tips.
If the test fails due to too much debris, clean end-face accordingly and retest.
ODC connector inspection
2. Inspect the ODC fiber end-face using the approved test equipment probe and the appropriated ODC
plug and ODC socket fiber tips.
If the test fails due to too much dirt clean end-face accordingly and re-
test.
a.
Unscrew the ODC cap (
Caution!
Protect cap against dust during the testing process).
b.
Insert ODC plug or socket tips into the ODC plug or socket connector as shown in figure A, B
and
inspect each connector (
Caution!
Make sure that tip is inserting fully into the connector to prevent any
false image or damage).
c.
Adjust inspection probe zoom until image can be viewed clearly.
Important Note:
In the event of failure, clean connectors as shown below, refer to optical fiber cleaning
section within this document for additional cleaning suggestions.
LC end-face inspection
Fail
Pass
ODC plug, Figure A
ODC socket, Figure B