RFS INSTALLATION GUIDELINES
HYBRIFLEX
®
CABLE|603400210500|September 2020
Visit
for the most current product specifications
Page 38 of 43
Engage the compression nut thread to the body 3-4 revolutions to keep the grommet in place but do not
tighten fully to allow for adjustment during RRU connection.
a)
Remove protective dust cap (top), disengage the compression nut (bottom), adjust the jumper to
proper length
Slide FullAXS compatible gland body down jacketing to allow access to the fiber end connector. Do not pull the
fiber end connector through the sleeve or damage may occur.
Remove the fiber dust caps from fiber end-face and seat into the RRH SPF card slot until you hear a click. Do
not twist fiber end-face or kink the fiber during installation.
Slide the FullAXS compatible sleeve up to the RRH. Turn top nut clockwise to secure to RRH bulkhead
connector.
6
5
4
7