Finish threading the compression nut to complete the installation.
Thread compression nut until it bottoms out (no gap) with the extended (front) inner body.
Reverse steps 6 to 1 to remove sleeve for maintenance. Note: Once the Nut is tight, spring fingers are
compressed tightly. To remove or adjust jumper fiber the grommet must be push from the front using small
long-shaft screw driver
Caution!
Do not insert the screw driver blindly.
Heat Shrink exposed
8
No gap