background image

 

DTR_102-02-07-001_EN_f

 

Summary of Contents for 102-02-07

Page 1: ...TECHNICAL AND OPERATIONAL DOCUMENTATION IR remote control for the devices of ZA and ZB series Product code 102 02 07 Explanatory figure ...

Page 2: ...e format 5 5 6 Configuration of the time synchronisation time zones taking into account the daylight saving time and the Master Mode 6 5 7 Configuration of the display brightness 6 5 8 Configuration of the alarms 7 5 9 Configuration of the ECO mode 7 5 10 Configuration of the display font 8 5 11 Restoring the default settings 8 5 12 Configuration of the temperature offset 8 5 13 Configuration of t...

Page 3: ...60 C at the humidity below 99 RH 4 IR remote control construction 4 1 Device construction The figure shows the IR remote control construction3 det A function buttons det B IR trasmitter det C CR2025 battery det D place for a strap Fig 1 4 2 IR remote control dimensions All dimensions shown in the figures are given in mm Fig 2 1 The range of the remote control is specified to be 10m Please take int...

Page 4: ...figuration of the display font F9 Restoring the default settings F10 Configuration of the temperature offset F11 Configuration of the synchronisation of displaying F12 Displaying information about the signal strength or the disconnection of the GPS module Table 1 5 1 Pairing of the IR remote control with the RGB Technology devices For the RGB Technology devices with the IR control module after con...

Page 5: ...DTR_102 02 07 001_EN_f 5 ...

Page 6: ... the configuration menu by pressing the MENU key 2 Select the F2 function using the and keys and confirm it with the key 3 To activate displaying the clock C set Y using the and keys and confirm it with the key 4 Next using the and keys modify the clock display time Cd and confirm it with the key 5 To activate the display of the date d set Y using the and keys and confirm it with the key 6 Next us...

Page 7: ...ain menu press the key NOTICE The satellite synchronisation requires the GPS module The network synchronisation requires the network module and the Internet access NOTICE For the Polish official time you should enter the UTC 1 G 01 time zone and activate taking into account the daylight saving time dst y NOTICE The Master Mode cannot be activated if the reference clock does not have the active GPS...

Page 8: ...he alarm duration period in seconds t and confirm it with the key 7 Using the and keys select your preferred alarm mode ALLd every day SELd selected days and confirm it with the key 8 If you choose the SELd mode selected days you should subsequently select the days in which the alarm is to be active e g active on Monday d1 Y inactive on Monday d1 n every time proceeding by using the key d1 Monday ...

Page 9: ...value within the range of 9 9 C and confirm it with the key Of Y yes Of N no 5 13 Configuration of the synchronisation of displaying To configure the synchronisation of displaying content using the remote control you should 1 Call the configuration menu pressing the MENU key 2 Select the F11 function using the keys and and confirm it with the key 3 Using the keys and select SC Y and confirm it wit...

Page 10: ...there is no time interval between 01 00UTC TimeZone and 01 59UTC TimeZone If you try to set the clock to the time within this interval one hour earlier value is adopted and it is assumed that the time has not yet been changed to the daylight saving time As a result within the nearest 60 minutes the clock will take into account the change to the daylight saving time and will add one hour automatica...

Reviews: