background image

 

DTR_314-01-01-001_EN_d

 

4.2

 

Autolearn function 

The Autolearn mode is enabled by default (position no. 0 is set in the 'proto' submenu). In order to disable it, 
the  communication  protocol  must  be  set  manually  using  the  embedded  user  menu  or  the  RGB  WagSet  2 
software.  
 
When this mode is active, each time the device is started, it detects the parameters of the communication with 
the  weighing  terminal  and  analyses  the  structure  of  the  data  frames  it  sends.  Then  it  adjusts  the  remote 
display's  settings  to  enable  correct  communication  with  the  terminal.  The  whole  operation  lasts  several 
seconds, depending on the baud rate and the time intervals between consecutive frames. All  remote display’s 
communication interfaces are supported, i.e. RS232/RS485/CL and the Ethernet (optional interface)

4

 
The Autolearn procedure is as follows: 
1. 

Baud rate detection - dot 1 flashing on the display 

2. 

Baud rate verification - dot 1 solid, dot 2 flashing 

3. 

Analysis of the protocol and its frame structure - dots 1 and 2 solid, dot 3 flashing 

 
During the analysis of the protocol and its frame structure, the measurement unit sent is also recognised. The 
following tags are recognised - "kg" 'K' " t" 'T' 't' " g" "gr" 'G' 'g' "lb" 'L' 'l' "oz" 'o' 'O'. In case the terminal does 
not  send  a  unit or  sends  a  unit  that  is  not  recognised  by  the  Autolearn  function,  the  default  unit  will  be  set. 
Depending on the purchased regional version, it is "kg" or "lb". 
 
The Autolearn mode supports the following transmission parameters: 
 
Baud rate: 

2400, 4800, 9600, 19200 

Transmission  parameters  (data  bits, 
parity, stop bits): 

8N1, 7E1, 7O1 

 

4.3

 

WA-1 MINI manual configuration 

The configuration of the device using RGB WagSet 2 enables, among others:  

1)

 

Precise defining the communication protocol with any weighing terminal, 

2)

 

Defining the reaction to the  events  reported  by  the weighing terminal (eg. overloading,  underloading, 
instability, etc.), 

3)

 

Entering advertising text.  

4.3.1

 

Defining communication protocols  

4.3.1.1

 

Embedded user menu (micro switch) 

The user menu embedded in the device allows you to select the communication protocol, display the information 
about the software version, reset the device to the default settings. The micro switch, used to operate the menu, 
is located inside the display housing. It is described as "DEF" (Fig. 4). Before you start the configuration process, 
it is necessary to unscrew the screws (Fig. 4, det. B) and remove the cover (Fig. 4, det. A). 

 

 

det. A

 – extender cover; 

det. B

 – screws fixing the cover 

Fig. 4 

 

 

                                                           

4

 If first the data is sent via the Ethernet to the display and then one of the other interfaces, i.e. RS232 / RS485 / CL is connected - the Autolearn procedure will be carried out again in order to determine the UART parameters and the protocol (the 

protocol for serial interfaces may differ from the Ethernet protocol). 

Summary of Contents for KAZEL WA-1 MINI

Page 1: ...OPERATION AND MAINTENANCE MANUAL WA 1 MINI Product code 314 01 01 Explanatory figure ...

Page 2: ...otocols 5 4 3 1 1 Embedded user menu micro switch 5 4 3 1 2 Interface transmission parameters and communication speed 6 4 3 1 3 RGB WagSet 2 software 6 5 MINI extender 7 5 1 Extender Connectors 7 5 2 List of extender connectors in the WA 1 MINI display for weighing scales 7 5 2 1 RS 232 connector 7 5 2 2 RS 485 RS 422 connector 7 5 2 3 0 20mA digital current loop 7 6 Automatic brightness control o...

Page 3: ...ansportation Due to protective packaging the device should be stored in the temperature 25 C 60 C 13 F 140 F at the humidity below 99 RH 3 Device construction WA 1 MINI has a housing made of polycarbonate which is resistant to UV radiation and has a high mechanical strength By using the thermo moulded housing and a rear sealing layer the device when properly assembled meets the IP66 tightness requ...

Page 4: ...ion or improper use may cause the property damage loss of health or death from electrical shock In addition any failure to follow the manufacturer s instructions may void your warranty NOTICE Keep in mind that the device should be mounted with the wires facing down NOTICE It is forbidden to make any additional mounting points or any holes in the device assembly components and in the device itself ...

Page 5: ...d by the Autolearn function the default unit will be set Depending on the purchased regional version it is kg or lb The Autolearn mode supports the following transmission parameters Baud rate 2400 4800 9600 19200 Transmission parameters data bits parity stop bits 8N1 7E1 7O1 4 3 WA 1 MINI manual configuration The configuration of the device using RGB WagSet 2 enables among others 1 Precise definin...

Page 6: ...g down the microbutton until the message Saved appears while exiting the custm option happens automatically after 30 seconds of user inactivity 4 reset This option allows you to restore the default settings of the remote display and to activate the Autolearn mode In addition in the devices with the Ethernet interface you can restore the default network layer settings IP address 192 168 0 11 networ...

Page 7: ...e line should be connected with the weighing terminal TDX output CK GND line of the current loop interface RS 485 RS 422 A RS 485 and RS 422 interface non inverting line B RS 485 and RS 422 interface inverting line GND GND line of the RS 485 and RS 232 interface for use at risk of a significant difference in the potentials of the display mass and the weighing terminal mass Table 2 5 2 1 RS 232 con...

Page 8: ...end the configuration to the display for weighing scales If the user does not enter the configuration the display will start the Autolearn procedure If the process is successful the Ready text is shown and then the unit is ready to show weighting results 8 Disposal and recycling 8 1 Recycling of packing materials The packaging materials must be segregated then recycled in accordance with local reg...