background image

 

DTR_314-01-01-001_EN_d

 

NOTICE! 

The  disassembly  of  the  housing  must  be  made  with  the  disconnected  power  supply.  When  doing  this,  take 
special caution because of the possibility of electric shock. 

The user menu is called up by pressing and holding  the "DEF" micro switch and releasing it when the desired 
option  is  displayed.  Regardless  of  the  option,  you  can  exit  the  user  menu  by  pressing  the  microbutton    and 
releasing  it  when  switching  between  the  options  (when  switching  between  the  options,  the  display  does  not 
display any information). 

The user menu has the following options: 

1)

 

info - This option allows you to display the device software version. For the displays with the Ethernet interface, 
the network layer settings are additionally provided (an IP address, a network mask, a communication port for 
the  RGB  WagSet  2  software  and  a  communication  port  for  the  weighing  terminal).  Exiting  the  info  option 
happens automatically after displaying the information. 

2)

 

proto  -  This  option  allows  you  to  select  the  display  communication  protocol  to  work  with  the  selected 
weighing  terminals  (Tab.  1).  You  can  change  the  protocol  by  short  pressing  the  microbutton.  Saving  the 
selected  protocol  is  accomplished  by  long  holding  down  the  microbutton  (until  the  message  "Saved" 
appears). Exiting the "proto" option happens automatically after 30 seconds of user inactivity. 

3)

 

custm  -  The  "custm"  option  allows  you  to  select  the  display  communication  protocol  to  work  with  the 
weighing  terminals  of  the  selected  clients.  These  protocols  have  special,  custom  settings  needed  for  the 
given client. Setting the protocol is done in the same way as in the case of the "proto" option - saving the 
selected  protocol  is  accomplished  by  long  holding  down  the  microbutton  (until  the  message  "Saved" 
appears), while exiting the "custm" option happens automatically after 30 seconds of user inactivity. 

4)

 

reset  -  This  option  allows  you  to  restore  the  default  settings  of  the  remote  display  and  to  activate  the 
Autolearn  mode.  In  addition,  in  the  devices  with  the  Ethernet  interface,  you  can  restore  the  default 
network layer settings (IP address: 192.168.0.11, network mask: 255.255.255.0, configuration port for the 
RGB WagSet 2 software: 2101, communication port for the weighing terminal: 2102). To restore the default 
settings  you  should,  during  the  normal operation  of  the  device,  press  the  microbutton  and  hold  it  down 
until the message "reset" appears. Hold the button down until the message "reset" starts  flashing and do 
not release it until the message "default" is displayed. Releasing the button before the message "default" 
appears will result in interrupting the process of restoring the default settings and the display will continue 
working according to the previously set parameters. Uploading new network settings is only possible using 
the RGB WagSet 2 software  available at www.kazel-displays.com 

4.3.1.2

 

Interface transmission parameters and communication speed  

Interface 

Transmission parameters 

Communication speed 

RS232, RS485, RS422, CL 

Data bits: 7, Parity: Odd, Even 
Data bits: 8, Parity:  None, Odd, Even 
Stop bits: 1 

300, 600, 1200, 2400, 4800, 9600, 
14400, 19200, 28800, 38400, 57600, 
76800, 115200, 230400 

Table 1 

 

4.3.1.3

 

RGB WagSet 2 software 

Using the WagSet 2 software, you can perform the advanced configuration of the device. The program allows you 
to change, among others: the parameters of displaying a weighing result, entering and editing advertising text, 
the display response to special situations such as: exceeded measurement range, etc. The detailed information on 
the configuration from your computer can be found in the manual supplied with the RGB WagSet 2 program. 
 

 

Summary of Contents for KAZEL WA-1 MINI

Page 1: ...OPERATION AND MAINTENANCE MANUAL WA 1 MINI Product code 314 01 01 Explanatory figure ...

Page 2: ...otocols 5 4 3 1 1 Embedded user menu micro switch 5 4 3 1 2 Interface transmission parameters and communication speed 6 4 3 1 3 RGB WagSet 2 software 6 5 MINI extender 7 5 1 Extender Connectors 7 5 2 List of extender connectors in the WA 1 MINI display for weighing scales 7 5 2 1 RS 232 connector 7 5 2 2 RS 485 RS 422 connector 7 5 2 3 0 20mA digital current loop 7 6 Automatic brightness control o...

Page 3: ...ansportation Due to protective packaging the device should be stored in the temperature 25 C 60 C 13 F 140 F at the humidity below 99 RH 3 Device construction WA 1 MINI has a housing made of polycarbonate which is resistant to UV radiation and has a high mechanical strength By using the thermo moulded housing and a rear sealing layer the device when properly assembled meets the IP66 tightness requ...

Page 4: ...ion or improper use may cause the property damage loss of health or death from electrical shock In addition any failure to follow the manufacturer s instructions may void your warranty NOTICE Keep in mind that the device should be mounted with the wires facing down NOTICE It is forbidden to make any additional mounting points or any holes in the device assembly components and in the device itself ...

Page 5: ...d by the Autolearn function the default unit will be set Depending on the purchased regional version it is kg or lb The Autolearn mode supports the following transmission parameters Baud rate 2400 4800 9600 19200 Transmission parameters data bits parity stop bits 8N1 7E1 7O1 4 3 WA 1 MINI manual configuration The configuration of the device using RGB WagSet 2 enables among others 1 Precise definin...

Page 6: ...g down the microbutton until the message Saved appears while exiting the custm option happens automatically after 30 seconds of user inactivity 4 reset This option allows you to restore the default settings of the remote display and to activate the Autolearn mode In addition in the devices with the Ethernet interface you can restore the default network layer settings IP address 192 168 0 11 networ...

Page 7: ...e line should be connected with the weighing terminal TDX output CK GND line of the current loop interface RS 485 RS 422 A RS 485 and RS 422 interface non inverting line B RS 485 and RS 422 interface inverting line GND GND line of the RS 485 and RS 232 interface for use at risk of a significant difference in the potentials of the display mass and the weighing terminal mass Table 2 5 2 1 RS 232 con...

Page 8: ...end the configuration to the display for weighing scales If the user does not enter the configuration the display will start the Autolearn procedure If the process is successful the Ready text is shown and then the unit is ready to show weighting results 8 Disposal and recycling 8 1 Recycling of packing materials The packaging materials must be segregated then recycled in accordance with local reg...

Reviews: