NOTICE!
The disassembly of the housing must be made with the disconnected power supply. When doing this, take
special caution because of the possibility of electric shock.
The user menu is called up by pressing and holding the "DEF" micro switch and releasing it when the desired
option is displayed. Regardless of the option, you can exit the user menu by pressing the microbutton and
releasing it when switching between the options (when switching between the options, the display does not
display any information).
The user menu has the following options:
1)
info - This option allows you to display the device software version. For the displays with the Ethernet interface,
the network layer settings are additionally provided (an IP address, a network mask, a communication port for
the RGB WagSet 2 software and a communication port for the weighing terminal). Exiting the info option
happens automatically after displaying the information.
2)
proto - This option allows you to select the display communication protocol to work with the selected
weighing terminals (Tab. 1). You can change the protocol by short pressing the microbutton. Saving the
selected protocol is accomplished by long holding down the microbutton (until the message "Saved"
appears). Exiting the "proto" option happens automatically after 30 seconds of user inactivity.
3)
custm - The "custm" option allows you to select the display communication protocol to work with the
weighing terminals of the selected clients. These protocols have special, custom settings needed for the
given client. Setting the protocol is done in the same way as in the case of the "proto" option - saving the
selected protocol is accomplished by long holding down the microbutton (until the message "Saved"
appears), while exiting the "custm" option happens automatically after 30 seconds of user inactivity.
4)
reset - This option allows you to restore the default settings of the remote display and to activate the
Autolearn mode. In addition, in the devices with the Ethernet interface, you can restore the default
network layer settings (IP address: 192.168.0.11, network mask: 255.255.255.0, configuration port for the
RGB WagSet 2 software: 2101, communication port for the weighing terminal: 2102). To restore the default
settings you should, during the normal operation of the device, press the microbutton and hold it down
until the message "reset" appears. Hold the button down until the message "reset" starts flashing and do
not release it until the message "default" is displayed. Releasing the button before the message "default"
appears will result in interrupting the process of restoring the default settings and the display will continue
working according to the previously set parameters. Uploading new network settings is only possible using
the RGB WagSet 2 software available at www.kazel-displays.com
4.3.1.2
Interface transmission parameters and communication speed
Interface
Transmission parameters
Communication speed
RS232, RS485, RS422, CL
Data bits: 7, Parity: Odd, Even
Data bits: 8, Parity: None, Odd, Even
Stop bits: 1
300, 600, 1200, 2400, 4800, 9600,
14400, 19200, 28800, 38400, 57600,
76800, 115200, 230400
Table 1
4.3.1.3
RGB WagSet 2 software
Using the WagSet 2 software, you can perform the advanced configuration of the device. The program allows you
to change, among others: the parameters of displaying a weighing result, entering and editing advertising text,
the display response to special situations such as: exceeded measurement range, etc. The detailed information on
the configuration from your computer can be found in the manual supplied with the RGB WagSet 2 program.