6.

 

Automatic brightness control of the display for weighing scales 

6.1

 

Lighting sensor  

In the standard version, the display for weighing scales has a lighting sensor included, which is placed on the LED 
panel. The device, in response to the intensity of daylight, adjusts the brightness of the display for weighing scales. 

7.

 

Initial start-up  

Step 1:  Make sure that all cables are properly connected,  
Step 2:  Make sure that all components have been installed in the correct orientation 

(wires down)

Step 3:  Connect the device to the mains power source,  
Step 4:  If properly connected, the system will display moving arrows (<<<<), followed by the symbol of a hard
 

space (_) shown in the bottom right corner, which means that the user has 7 seconds to send the

 

configuration to the display for weighing scales. If the user does not enter the configuration, the display

 

will start the Autolearn procedure. If the process is successful  the "Ready" text is shown and then the 

 

unit is ready to show weighting results. 

8.

 

Disposal and recycling 

8.1

 

 Recycling of packing materials 

The packaging materials must be segregated , then recycled in accordance with local regulations for 
waste disposal regulations. 

 

8.2

 

 Disposal of the device 

The device can not be disposed with regular household waste!  
According to Directive 2002 / 96 / EC ( WEEE ) , when repair is not economically reasonable, user is 
obligated to hand over damaged or destroyed device to an appropriate disposal facility . 

 

 

9.

 

Most common errors during the installation  

1

 

Incorrect configuration uploaded to the display for weighing scales.  

2

 

Drilling additional mounting holes.  

 

Because the product is constantly developed, presented data is subject to change without notice. 

Summary of Contents for KAZEL WA-1 MINI

Page 1: ...OPERATION AND MAINTENANCE MANUAL WA 1 MINI Product code 314 01 01 Explanatory figure ...

Page 2: ...otocols 5 4 3 1 1 Embedded user menu micro switch 5 4 3 1 2 Interface transmission parameters and communication speed 6 4 3 1 3 RGB WagSet 2 software 6 5 MINI extender 7 5 1 Extender Connectors 7 5 2 List of extender connectors in the WA 1 MINI display for weighing scales 7 5 2 1 RS 232 connector 7 5 2 2 RS 485 RS 422 connector 7 5 2 3 0 20mA digital current loop 7 6 Automatic brightness control o...

Page 3: ...ansportation Due to protective packaging the device should be stored in the temperature 25 C 60 C 13 F 140 F at the humidity below 99 RH 3 Device construction WA 1 MINI has a housing made of polycarbonate which is resistant to UV radiation and has a high mechanical strength By using the thermo moulded housing and a rear sealing layer the device when properly assembled meets the IP66 tightness requ...

Page 4: ...ion or improper use may cause the property damage loss of health or death from electrical shock In addition any failure to follow the manufacturer s instructions may void your warranty NOTICE Keep in mind that the device should be mounted with the wires facing down NOTICE It is forbidden to make any additional mounting points or any holes in the device assembly components and in the device itself ...

Page 5: ...d by the Autolearn function the default unit will be set Depending on the purchased regional version it is kg or lb The Autolearn mode supports the following transmission parameters Baud rate 2400 4800 9600 19200 Transmission parameters data bits parity stop bits 8N1 7E1 7O1 4 3 WA 1 MINI manual configuration The configuration of the device using RGB WagSet 2 enables among others 1 Precise definin...

Page 6: ...g down the microbutton until the message Saved appears while exiting the custm option happens automatically after 30 seconds of user inactivity 4 reset This option allows you to restore the default settings of the remote display and to activate the Autolearn mode In addition in the devices with the Ethernet interface you can restore the default network layer settings IP address 192 168 0 11 networ...

Page 7: ...e line should be connected with the weighing terminal TDX output CK GND line of the current loop interface RS 485 RS 422 A RS 485 and RS 422 interface non inverting line B RS 485 and RS 422 interface inverting line GND GND line of the RS 485 and RS 232 interface for use at risk of a significant difference in the potentials of the display mass and the weighing terminal mass Table 2 5 2 1 RS 232 con...

Page 8: ...end the configuration to the display for weighing scales If the user does not enter the configuration the display will start the Autolearn procedure If the process is successful the Ready text is shown and then the unit is ready to show weighting results 8 Disposal and recycling 8 1 Recycling of packing materials The packaging materials must be segregated then recycled in accordance with local reg...

Reviews: