background image

 

 

 

6. DO NOT USE A WRONG FITTING. 

The connector on the tool must not hold pressure when air supply is disconnected. If a wrong 
fitting is used, the tool can remain charged with air after disconnecting and thus will be able to 
drive a fastener even after the line of air is disconnected, possibly causing injury. 
 

7. DISCONNECT THE AIR SUPPLY AND EMPTY THE MAGAZINE WHEN THE TOOL IS 
NOT IN USE. 

Always disconnect the air supply from the tool and empty the magazine when operation has 
been completed or suspended, when unattended, moving to a different work area, adjusting, 
disassembling, or repairing the tool, and when clearing a jammed fastener. 
 

8. INSPECT SCREW TIGHTNESS. 

Loose or improperly installed screws or bolts cause accidents and tool damage when the tool 
is put into operation. Inspect to confirm that all screws and bolts are tight and properly installed 
prior to operating the tool. 
 

9. DO NOT TOUCH THE TRIGGER UNLESS YOUR INTEND TO DRIVER A FASTENER. 

Whenever the air supply is connected to the tool, never touch the trigger unless you intend to 
drive a fastener into the work. It is dangerous to walk around carrying the tool with the trigger 
pulled, and this and similar actions should be avoided. 
 

10. NEVER POINT THE DISCHARGE OUTLET TOWARD YOURSELF AND PERSONNEL. 

If the discharge outlet is pointed toward people, serious accidents may be caused when 
misfiring. Be sure the discharge outlet is not pointed toward people when connecting and 
disconnecting the hose. Loading and not loading the fasteners or similar operations

 
11. USE SPECIFIED FASTENERS. 

The use of fasteners other than specified fasteners will cause the tool malfunction. Be sure to 
use only specified fasteners when operating the tool.  
 

12. PLACE THE DISCHARGE OUTLET TO THE WORK PROPERLY.  

Failure to place the discharge outlet of the nose in a proper manner can result in a fastener 
flying up and is extremely dangerous. 
 

13. KEEP HANDS AND BODY AWAY FROM THE DISCHARGE OUTLET  

When loading and using the tool, never place a hand or any part of body in fastener discharge 
area of the tool. It is very dangerous to hit the hands or body by mistake. 
 

Summary of Contents for CN57

Page 1: ...understand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual...

Page 2: ...ailers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing approp...

Page 3: ...essional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident prevent...

Page 4: ...vels which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER...

Page 5: ...henever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and...

Page 6: ...may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at...

Page 7: ...ine capacity 300 350 nails Maximum allowable pressure 8 3 bar 120psi Recommended pressure range 5 bar to 7 bar 70psi to 100psi Fasteners Only the nail sizes shown in the table below can be driven with...

Page 8: ...ply compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The fema...

Page 9: ...wood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air f...

Page 10: ...itting the hands or body by mistake Nail loading 1 Disconnect the air hose 2 Press LATCH 210690 to open DOOR 210360 then open MAGAZINE COVER 420800 3 Adjust the height of NAIL SUPPORT 321360 according...

Page 11: ...the nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In...

Page 12: ...O RING 16X1 8 22 410210 BUMPER 70 420090 TRIGGER VLAVE CAGE 23 322740 SAFETY 71 420800 MAGAZINE COVER 24 210670 NOSE 72 420240 SPRING HOLDER 25 420180 GUARD COVER 73 620650 MAGAZINE SPRING 26 511250...

Page 13: ...13 TOOL SCHEMATIC CN57...

Page 14: ...14 IMPORTER NOBE ApS Bj dstrupvej 10 DK 8410 R nde Denmark Tel 45 8615 1913 E Mail info nobe dk www nobe dk www rgneurope com Industrial Coil Nailer CN57 2016...

Reviews: