TM005 Rheem Solar Hiline Service Instructions REV D
D.O.I 20/02/2009
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
7
Product Changes
Frost Areas
The Hiline fitted with NPT collectors is not suitable for installation in frost areas. A Premier
Hiline must be installed if frost is likely to occur.
Operating Thermostat
The Robertshaw EWT1L2-552 thermostat (part number 051333) was replaced by the
Robertshaw ST1203133 thermostat (part number 052012) in August 2007.
It should be noted that although the ST series thermostat is a direct replacement for the
EWT series thermostat, the terminal connections and wiring arrangement is different.
Therefore;
Whenever an EWT series thermostat is replaced with a ST series thermostat,
rewiring at the thermostat will be required. Refer to wiring diagrams in
technical bulletin TB07 016 for wiring arrangements utilising the new ST
series thermostat.
PPS Connectors
Failed PPS connectors used to couple SCT/SBT collector arrays can be replaced with a
brass connector variant. The brass connectors are supplied in supplied in kit form with all
the necessary components required to replace the corresponding PPS connector (see
table below)
Connector
PPS Part Number
Brass Part Number
Collector inter-connector
195701
195701B
Hot connector
195702
195702B
End cap
195703
195703B
Cold connector
195704B
Refer to TB07 017 for further information regarding PPS connector replacement.
SCT/SBT Collector
The SCT and SBT collectors have been removed from sale. The NPT collector can be
used to replace the SCT and SBT collectors in non frost areas. Contact your nearest
Rheem Service Department if a SCT/SBT collector replacement is required in a frost prone
area. Refer to page 30 for further information regarding superseded collector models.