background image

Air

Standard & Optional Equipment

R801S (UF/HZ) Series

3

WARNING

THIS FURNACE IS NOT APPROVED

OR RECOMMENDED

FOR USE IN MOBILE HOMES

DIRECT SPARK IGNITOR

IN-SHOT BURNERS

DRAFT INDUCER MOTOR

PATENTED HEAT EXCHANGER

INTEGRATED

FURNACE

CONTROL

STANDARD EQUIPMENT

Completely assembled and wired; induced draft; pressure switch;
redundant main gas control; blower compartment door safety switch;
solid state time on/time off blower control; limit control; manual shut-
off valve, pressure regulator for natural and L.P. (propane) gas;
transformer; direct drive multi-speed blower motor. Furnaces are
equipped with cooling/heating relay and transformer (40VA) ready for
air conditioning applications. (Please note: a thermostat is not
included as standard equipment.) Flame sensor diagnostics.

OPTIONAL EQUIPMENT

Side and bottom filter frame assembly. Return air cabinet for all sizes.

NOTE: Furnace is not listed for use with fuels other than natural or L.P. 

(propane) gas.

The complete terms of limited and other warranties are available at our
sales office, or through local installer.

All models can be converted by a qualified Rheem distributor or local
service dealer to use L.P. (propane) gas without changing burners.
Factory approved kits must be used to convert from natural to L.P.
(propane) gas and may be ordered as optional accessories from a
Rheem parts distributor.

For L.P. (propane) operation, refer to Conversion Kit Index Form.

NOTE: For natural and L.P. (propane) gas models, direct spark ignition
is 100% safety lockout type.

Summary of Contents for classic R801S series

Page 1: ...lusOne Diagnostics 7 Segment LED all units PlusOne Ignition System DSI for reliability and longevity Heat exchanger is removable for improved serviceability Aluminized steel construction provides maxi...

Page 2: ...01S UF HZ Series 2 TABLE OF CONTENTS Standard Optional Equipment 3 Model Features Physical Data Specifications 4 Model Number Identification 5 Dimensional Data 6 7 Blower Performance Data 8 Accessorie...

Page 3: ...air conditioning applications Please note a thermostat is not included as standard equipment Flame sensor diagnostics OPTIONAL EQUIPMENT Side and bottom filter frame assembly Return air cabinet for al...

Page 4: ...Outlet Air Temp F C 155 68 3 155 68 3 180 82 2 165 73 8 190 87 7 Approx Shipping Weight Lbs kg 110 50 125 57 140 64 150 68 160 73 AFUE 80 0 80 0 80 0 80 0 80 0 NOTES All models are 115V 60HZ 1 Ph Gas...

Page 5: ...5 075 75 000 22 100 100 000 29 125 125 000 37 150 150 000 44 3 Up to 3 Ton 4 Up to 4 Ton 5 Up to 5 Ton Cabinet Width 14 14 0 17 17 5 21 21 0 24 24 5 M Multi X Low NOx S Standard Revision Marketing A F...

Page 6: ...1 2 64 0 0 0 1 25 3 76 6 152 120 54 4 125 241 2 622 2311 32 593 157 8 403 221 2 559 21 2 64 0 0 0 1 25 3 76 6 152 140 63 5 150 241 2 622 2311 32 593 157 8 403 221 2 559 21 2 64 0 0 0 1 25 3 76 6 152 1...

Page 7: ...559 21 2 64 0 0 0 1 25 3 76 6 152 140 63 5 150 241 2 622 2311 32 593 157 8 403 221 2 559 21 2 64 0 0 0 1 25 3 76 6 152 150 68 NOTES May require a 3 76 mm to 4 102 mm or 3 76 mm to 5 127 mm adapter 4 a...

Page 8: ...1728 1013 1113 1358 1657 970 1062 1306 1570 801SA100521M A 1 2 373 11 x 10 279 x 254 Low Med Lo Med Hi High 1209 1438 1902 2071 1182 1420 1883 2037 1131 1386 1844 2001 1112 1350 1817 1962 1051 1320 1...

Page 9: ...1 AE 61874 03 185 8 x 239 16 473 x 598 241 2 622 RXGB D24 AE 61874 04 255 8 x 239 16 651 x 598 FOR HIGH ALTITUDES OPTION CODE FOR HIGH ALTITUDE U S Canada None required for high altitudes HIGH ALTITUD...

Page 10: ...within the applicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions conta...

Page 11: ...Air Notes R801S UF HZ Series 11...

Page 12: ...mith Arkansas 72917 www rheem com In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice PRINTED IN U S A 5 15 QG FORM NO G11...

Reviews: