background image

2

• IF AIR-MOVING EQUIPMENT OR

DUCTWORK IS LOCATED IN
SPACES CONTAINING FUEL
BURNING APPLIANCES SUCH AS
WATER HEATERS OR BOILERS -
ALL JOINTS, SEAMS, AND OPEN-
INGS IN THE EQUIPMENT AND
DUCT MUST ALSO BE SEALED TO
PREVENT DEPRESSURIZATION OF
THE SPACE AND POSSIBLE
MIGRATION OF COMBUSTION
BYPRODUCTS INCLUDING CAR-
BON MONOXIDE INTO THE LIVING
SPACE.

IMPROPER INSTALLATION, OR
INSTALLATION NOT MADE IN
ACCORDANCE WITH THE CSA
INTERNATIONAL (CSA) CERTIFICA-
TION OR THESE INSTRUCTIONS,
CAN RESULT IN UNSATISFACTORY
OPERATION AND/OR DANGEROUS
CONDI-TIONS AND ARE NOT COV-
ERED BY THE UNIT WARRANTY.

IN COMPLIANCE WITH RECOG-
NIZED CODES, IT IS RECOMMEND-
ED THAT AN AUXILIARY DRAIN
PAN BE INSTALLED UNDER ALL
EVAPORATOR COILS OR UNITS
CONTAINING EVAPORATOR COILS
THAT ARE LOCATED IN ANY AREA
OF A STRUCTURE WHERE DAM-
AGE TO THE BUILDING OR BUILD-
ING CONTENTS MAY OCCUR AS A
RESULT OF AN OVERFLOW OF
THE COIL DRAIN PAN OR A STOP-
PAGE IN THE PRIMARY CONDEN-
SATE DRAIN PIPING. SEE ACCES-
SORIES SECTION OF THESE
INSTRUCTIONS FOR AUXILIARY
HORIZONTAL OVERFLOW PAN
INFORMATION (MODEL RXBM).

GENERAL INFORMATION

DUCT LEAKS CAN CREATE AN
UNBALANCED SYSTEM AND DRAW
POLLUTANTS SUCH AS DIRT, DUST,
FUMES AND ODORS INTO THE
HOME CAUSING PROPERTY DAM-
AGE. FUMES AND ODORS FROM
TOXIC, VOLATILE OR FLAMMABLE
CHEMICALS, AS WELL AS AUTO-
MOBILE EXHAUST AND CARBON
MONOXIDE (CO), CAN BE DRAWN
INTO THE LIVING SPACE THROUGH
LEAKING DUCTS AND UNBAL-
ANCED DUCT SYSTEMS CAUSING
PERSONAL INJURY OR DEATH (SEE
FIGURE 1).

• IF AIR-MOVING EQUIPMENT OR

DUCTWORK IS LOCATED IN
GARAGES OR OFF-GARAGE
STORAGE AREAS - ALL JOINTS,
SEAMS, AND OPENINGS IN THE
EQUIPMENT AND DUCT MUST BE
SEALED TO LIMIT THE MIGRA-
TION OF TOXIC FUMES AND
ODORS INCLUDING CARBON
MONOXIDE FROM MIGRATING
INTO THE LIVING SPACE.

WARNING

!

NOTICE

!

NOTICE

!

Summary of Contents for Prestige RGFE-09EZCMS

Page 1: ...from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Do not rely on smell alone to detect leaks Due to various factors you m...

Page 2: ...STRUCTURE WHERE DAM AGE TO THE BUILDING OR BUILD ING CONTENTS MAY OCCUR AS A RESULT OF AN OVERFLOW OF THE COIL DRAIN PAN OR A STOP PAGE IN THE PRIMARY CONDEN SATE DRAIN PIPING SEE ACCES SORIES SECTION...

Page 3: ...Edition National Electrical Code NFPA90A Installation of Air Conditioning and Ventilating Systems NFPA90B Installation of warm air heating and air conditioning systems The equipment has been evaluated...

Page 4: ...The furnace controller will optimize furnace performance by monitoring all thermostat and temperature inputs and insuring the stable operation of the inducer gas valve and indoor blower motor ECM Var...

Page 5: ...LOWER MOTOR 8 DOOR SWITCH 9 JUNCTION BOX 10 COMBUSTION AIR INLET 11 HALC 12 TOP PLATE 13 VENT CAP PLUG ITEM NO PART NAME 14 OUTLET AIR PIPE 15 INTEGRATED FURNACE CONTROL 16 TRANSFORMER 17 INDUCED DRAF...

Page 6: ...ing insulation Some materials may be combustible Any additions changes or conver sions required in order for the furnace to satisfactorily meet the application needs should be made by a qualified inst...

Page 7: ...dence Deterioration of the venting system or soot build up can cause leaks into the system Have a qualified installer service agency or the gas supplier replace damaged parts or repair obstructions in...

Page 8: ...trodes The main solenoid on the gas valve is energized allowing gas to flow to the burners When flame is proven the ignition con trol is de energized 8 second maxi mum trial time The gas valve maintai...

Page 9: ...the motor exterior And as suggested elsewhere in these instructions keep the air filters clean because dirty filters can restrict airflow and the motor depends on sufficient air flowing across and th...

Page 10: ...e condensate tube to make sure condensate flows freely while the furnace is in operation IMPORTANT IT IS RECOMMENDED THAT AT THE BEGINNING OF THE HEATING SEASON THE CONDENSATE TRAP BE INSPECTED BY A Q...

Page 11: ...11 FIGURE 12 DOWNFLOW CONNECTION A112001 S01 REFER TO INSTALLATION MANUAL FIGURE 11 UPFLOW CONDENSATE DRAIN A112001 S01 REFER TO INSTALLATION MANUAL...

Page 12: ...12 CM 0710 FIGURE 13 HORIZONTAL CONDENSATE DRAIN...

Reviews: