background image

5

FIGURE 3

HORIZONTAL FURNACE (-)GJD

ITEM

NO. PART NAME

1

GAS VALVE

2

CAPACITOR (FOR INDUCER)

3

LOW PRESSURE SWITCH

4

HIGH PRESSURE SWITCH

5

BLOWER HOUSING

6

POWER FACTOR CHOKE

7

BLOWER MOTOR

8

DOOR SWITCH

9

JUNCTION BOX

10 COMBUSTION AIR INLET

11 HALC

12 TOP PLATE

13 VENT CAP PLUG

ITEM

NO. PART NAME

14 OUTLET AIR PIPE

15 INTEGRATED FURNACE CONTROL

16 TRANSFORMER

17 INDUCED DRAFT BLOWER

18 CONNECTOR

19 EXHAUST TRANSITION

20 CONDENSATE TRAP

21 IGNITER

22 OVERTEMPERATURE SWITCH

23 BURNER

24 FLAME SENSOR

25 FACTORY-INSTALLED STREET ELBOW

ST-A107801.S01

Summary of Contents for Prestige RGFE-09EZCMS

Page 1: ...from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Do not rely on smell alone to detect leaks Due to various factors you m...

Page 2: ...STRUCTURE WHERE DAM AGE TO THE BUILDING OR BUILD ING CONTENTS MAY OCCUR AS A RESULT OF AN OVERFLOW OF THE COIL DRAIN PAN OR A STOP PAGE IN THE PRIMARY CONDEN SATE DRAIN PIPING SEE ACCES SORIES SECTION...

Page 3: ...Edition National Electrical Code NFPA90A Installation of Air Conditioning and Ventilating Systems NFPA90B Installation of warm air heating and air conditioning systems The equipment has been evaluated...

Page 4: ...The furnace controller will optimize furnace performance by monitoring all thermostat and temperature inputs and insuring the stable operation of the inducer gas valve and indoor blower motor ECM Var...

Page 5: ...LOWER MOTOR 8 DOOR SWITCH 9 JUNCTION BOX 10 COMBUSTION AIR INLET 11 HALC 12 TOP PLATE 13 VENT CAP PLUG ITEM NO PART NAME 14 OUTLET AIR PIPE 15 INTEGRATED FURNACE CONTROL 16 TRANSFORMER 17 INDUCED DRAF...

Page 6: ...ing insulation Some materials may be combustible Any additions changes or conver sions required in order for the furnace to satisfactorily meet the application needs should be made by a qualified inst...

Page 7: ...dence Deterioration of the venting system or soot build up can cause leaks into the system Have a qualified installer service agency or the gas supplier replace damaged parts or repair obstructions in...

Page 8: ...trodes The main solenoid on the gas valve is energized allowing gas to flow to the burners When flame is proven the ignition con trol is de energized 8 second maxi mum trial time The gas valve maintai...

Page 9: ...the motor exterior And as suggested elsewhere in these instructions keep the air filters clean because dirty filters can restrict airflow and the motor depends on sufficient air flowing across and th...

Page 10: ...e condensate tube to make sure condensate flows freely while the furnace is in operation IMPORTANT IT IS RECOMMENDED THAT AT THE BEGINNING OF THE HEATING SEASON THE CONDENSATE TRAP BE INSPECTED BY A Q...

Page 11: ...11 FIGURE 12 DOWNFLOW CONNECTION A112001 S01 REFER TO INSTALLATION MANUAL FIGURE 11 UPFLOW CONDENSATE DRAIN A112001 S01 REFER TO INSTALLATION MANUAL...

Page 12: ...12 CM 0710 FIGURE 13 HORIZONTAL CONDENSATE DRAIN...