56
TABLE 15
90 PLUS AIR FLOW PERFORMANCE
CFM @ ESP
MODEL
BLOWER/
SPEED
MOTOR HP
.1
.2
.3
.4
.5
.6
.7
UPFLOW MODELS
(-)GRL-04
11 X 7 /
1
⁄
2
LOW
805
780
760
720
685
645
605
*M-LO
920
885
850
810
775
730
690
M-HI
1140
1110
1085
1045
1010
950
890
HIGH
1360
1320
1280
1235
1195
1140
1080
(-)GRL-07(A)
11 X 7 /
1
⁄
2
LOW
780
745
710
675
640
595
555
M-LO
880
850
825
785
750
702
655
*M-HI
1090
1050
1010
970
925
875
825
HIGH
1300
1255
1210
1160
1110
1055
1005
(-)GRL-06
11 X 7 /
1
⁄
2
LOW
770
740
710
675
645
605
570
*M-LO
880
845
815
790
760
715
670
M-HI
1060
1025
990
960
925
880
835
HIGH
1260
1215
1175
1135
1100
1040
985
(-)GRL-07(B)
12 X 7 /
3
⁄
4
LOW
1105
1095
1080
1050
1030
1010
990
*M-LO
1290
1275
1260
1220
1195
1170
1140
M-HI
1480
1435
1415
1390
1370
1300
1255
HIGH
1705
1665
1615
1570
1540
1475
1400
(-)GRL-09**
12 X 11 /
3
⁄
4
LOW
1235
1210
1185
1150
1120
1075
1035
M-LO
1490
1465
1440
1405
1375
1315
1255
*M-HI
1720
1670
1620
1600
1580
1520
1460
HIGH
2100
2050
2000
1955
1910
1825
1745
(-)GRL-10**
12 X 11 /
3
⁄
4
LOW
1230
1205
1180
1155
1130
1090
1050
M-LO
1490
1445
1405
1375
1350
1295
1240
*M-HI
1710
1665
1620
1580
1540
1475
1410
HIGH
2010
1955
1900
1855
1810
1710
1610
(-)GRK-12**
11 X 10 /
3
⁄
4
LOW
1320
1305
1290
1260
1230
1185
1140
M-LO
1610
1580
1555
1515
1475
1415
1355
*M-HI
1870
1820
1775
1715
1660
1590
1520
HIGH
2115
2050
1990
1945
1900
1795
1690
DOWNFLOW/HORIZONTAL MODELS
(-)GTK-06
11 X 7 /
1
⁄
2
LOW
795
760
730
695
660
615
570
*M-LO
910
885
860
815
770
725
680
M-HI
1115
1080
1045
1005
965
920
875
HIGH
1365
1315
1270
1225
1180
1125
1070
(-)GTK-07(A)
11 X 7 /
1
⁄
2
LOW
780
750
720
675
635
595
555
M-LO
890
860
835
790
750
705
660
*M-HI
1100
1060
1025
980
940
890
845
HIGH
1340
1295
1250
1200
1150
1090
1025
(-)GTK-07(B)
11 X 7 /
3
⁄
4
LOW
1185
1160
1140
1115
1095
1065
1040
*M-LO
1405
1375
1350
1310
1270
1235
1195
M-HI
1595
1560
1525
1480
1440
1380
1325
HIGH
1835
1780
1730
1675
1625
1555
1480
(-)GTK-09
12 X 11 /
3
⁄
4
LOW
1155
1125
1100
1080
1060
1000
940
*M-LO
1420
1400
1380
1365
1350
1260
1175
M-HI
1605
1575
1550
1560
1570
1480
1390
HIGH
2005
1965
1930
1890
1850
1765
1680
(-)GTK-10
12 X 11 /
3
⁄
4
LOW
1180
1150
1120
1100
1080
1025
970
*M-LO
1460
1425
1390
1375
1360
1280
1200
M-HI
1680
1645
1615
1585
1560
1490
1420
HIGH
2055
2000
1940
1880
1820
1745
1675
(-)GTK-12
11 X 10 /
3
⁄
4
LOW
1285
1250
1215
1235
1260
1230
1200
*M-HI
1590
1565
1540
1505
1475
1425
1375
M-HI
1840
1820
1800
1750
1700
1645
1590
HIGH
2315
2250
2185
2110
2040
1965
1890
* Factory-Set High Heating speed
A = 17
1
⁄
2
"Cabinet Size
B = 21"Cabinet Size
NOTE: CFM valves represent furnace-only airflow ratings.
**Where the maximum air flow is above 1800 CFM, we recommend both sides or 1 side and bottom to be used to maximize air flow.
Summary of Contents for RGRK SERIES
Page 41: ...41 FIGURE 39 TYPICAL MANIFOLD PRESSURE READING...
Page 45: ...45 FIGURE 43 UT Electronic Controls 1095 201 IFC TWINNING CONNECTION SINGLE STAGE OPERATION...
Page 60: ...60 FIGURE 53 TROUBLESHOOTING CHART or IFC not properly grounded Go To Next Page...
Page 61: ...61 FIGURE 53 TROUBLESHOOTING CHART CONTINUED...
Page 62: ...62 FIGURE 54 WIRING DIAGRAM...
Page 63: ...63...
Page 64: ...64 CM 0510...