Air

Accessories

RGRS/RGRT Series

8

UPFLOW ACCESSORIES

FILTER RACK FILTER SIZES* INCHES [mm]

10

19

1

/

4

x 25

[489 x 635]

15

3

/

4

x 25

[400 x 635]

12

MODEL

RGRS/RGRT-

RXGF-CB

(BOTTOM)

RXGF-CA

(SIDE)

22

3

/

4

x 25

[578 x 635]

15

3

/

4

x 25

[400 x 635]

04

15

3

/

4

x 25

[400 x 635]

15

3

/

4

x 25

[400 x 635]

06

15

3

/

4

x 25

[400 x 635]

15

3

/

4

x 25

[400 x 635]

07EE

15

3

/

4

x 25

[400 x 635]

15

3

/

4

x 25

[400 x 635]

07EF

19

1

/

4

x 25

[489 x 635]

15

3

/

4

x 25

[400 x 635]

09

19

1

/

4

x 25

[489 x 635]

15

3

/

4

x 25

[400 x 635]

FURNACE

WIDTH

IN. [mm]

PLENUM

WIDTH

IN. [mm]

PLENUM ADAPTER

UPFLOW

COIL

PLENUM

14

1

/

2

[356]

16

1

/

4

[413]

RXAA-C171

RXAL-B16BU

14

1

/

2

[356]

20

1

/

4

[514]

RXAA-C172

RXAL-B20BU

17

1

/

2

[445]

16

1

/

4

[413]

RXAA-C185

RXAL-B16BU

17

1

/

2

[445]

20

1

/

4

[514]

RXAA-C173

RXAL-B20BU

17

1

/

2

[445]

21

5

/

8

[549]

RXAA-C187

RXAL-B21BU

17

1

/

2

[445]

25

1

/

4

[641]

RXAA-C174

RXAL-B25BU

21

1

/

2

[533]

25

1

/

4

[641]

RXAA-C175

RXAL-B25BU

21

1

/

2

[533]

22

1

/

4

[565]

RXAA-C176

RXAL-B22BU

24

1

/

2

[622]

25

1

/

4

[641]

RXAA-C177

RXAL-B25BU

24

1

/

2

[622]

21

5

/

8

[549]

RXAA-C187

RXAL-B21BU

21

1

/

2

[533]

21

5

/

8

[549]

RXAA-C188

RXAL-B21BU

PLENUM DATA FOR “A” COILS

Plenum adapters are required in some instances for use on upflow
applications when plenum and furnace size do not match.

VENT TERMINATION KITS CONCENTRIC: 
HORIZONTAL/VERTICAL =

RXGY-E03A 

(US & Canadian Installations)

HORIZONTAL TWO PIPE:

RXGY-D02, RXGY-D03, RXGY-D04 

(US Installations)

RXGY-D02A, RXGY-D03A, RXGY-D04A

(Canadian Installations)

RXGY-G02

(US Only)

NEUTRALIZER KIT:

RXGY-A01

FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA)

RETURN AIR PLENUM:

RXGR-C17B
RXGR-C21B
RXGR-C24B

EXTERNAL BOTTOM FILTER RACK:

RXGF-CB

EXTERNAL SIDE FILTER RACK:

RXGF-CA

*Filter racks are shipped without filters.

Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.

INTERNAL FILTER RACK FOR BOTTOM
OR SIDE RETURN:

RXGF-DA*

Each order contains (1) one box of 10 filter racks supplied
without filters.

*Filters available through PROSTOCK

®

.

RXGP-F03

TWINNING KIT

—is for use with Rheem 

Value Series 90 Gas Furnaces for

parallel operation requirements.

WARNING: IMPORTANT NOTICE

A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS
INSTALLED WITH SIDE OR REAR AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE
COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE
AND CREATE POTENTIALLY HAZARDOUS CONDITIONS. SOLID BOTTOM IS AVAILABLE
FACTORY INSTALLED WITH OPTION CODE 

263

.

FURNACE

BASE

WIDTH

SOLID BOTTOM

BASE

PLATE SIZE

IN. [mm]

KIT NO.

PLATE NO.

IN. [mm]

17

1

/

2

[445]

RXGB-D17

AE-61874-02

15

1

/

8

x 23

9

/

16

[384 x 598]

21

[533]

RXGB-D21

AE-61874-03

18

5

/

8

x 23

9

/

16

[473 x 598]

24

1

/

2

[622]

RXGB-D24

AE-61874-04

25

5

/

8

x 23

9

/

16

[651 x 598]

FOR HIGH ALTITUDES:

*HIGH ALTITUDE KIT:

RXGY-F04 (105 KBTU/H)
RXGY-F05 (120 KBTU/H)
RXGY-F06 (45 KBTU/H/60 KBTU/H/90 KBTU/H)
RXGY-F07 (75 KBTU/H)

*For installations over 5000 ft.

OPTION CODE FOR HIGH ALTITUDE:

US & Canada – 278

NOTE:

High altitude kits and options do NOT include additional burner orifices.
If a burner orifice change is necessary, they must be ordered through
PROSTOCK

®

. See Installation Instructions for more information.

Option – 278 furnaces are shipped with #51 DMS orifices installed. This is
one drill size smaller than standard furnaces to account for expected average
elevations and heating values typically seen in these areas.

CAUTION:

Always follow National Fuel Gas Code (NFGC) guidelines when

converting for high altitudes.

For all installations above 2000 ft. (including all option – 278 models), the
burner orifice size needs to be recalculated and verified. A burner orifice
change may still be required. See Installation Instructions for more
information.

NOTE:

For Canadian installations only, an optional derate (manifold gas
pressure reduction) method may be used to adjust the furnace for
altitude. See Installation Instructions for more information. This
optional method may 

NOT

be used for U.S. installations.

[    ] Designates Metric Conversions

Summary of Contents for RGRS SERIES

Page 1: ...ctric and condensate drainage connections on upflow models Integrated control board manages all operational functions and provides accessory hookups for an electronic air cleaner A slow opening gas va...

Page 2: ...GRS RGRT Series 2 TABLE OF CONTENTS Standard Optional Equipment 3 Model Features Physical Data Specifications 4 Model Number Identification 5 Dimensional Data 6 Blower Performance Data 7 Accessories 8...

Page 3: ...ive multi speed blower motor Please note a thermostat is not included as standard equipment OPTIONAL EQUIPMENT See Accessory Page NOTE Furnace is not listed for use with fuels other than natural or L...

Page 4: ...65 19 4 36 1 50 80 27 8 44 4 Approx Shipping Weight Lbs kg 111 50 3 117 53 1 123 55 8 123 55 8 148 67 1 152 68 9 AFUE 93 5 92 5 92 8 92 0 93 5 92 0 9 5 Low High 15 037 50 12 1465 691 108 000 31 65 19...

Page 5: ...4 Y 12 x 7 305 x 178 Z 12 x 11 305 x 279 Heating Input Designation Design Series S 3rd Design Series T 4th Design Series R Upflow Condensing R H E E M Electric Ignition 04E 06E 07E 09E 10E 12E Input B...

Page 6: ...2 1325 32 352 0 0 0 1 25 2 51 0 117 53 07EM 171 2 445 1611 32 415 155 8 397 2 51 15 422 1325 32 352 0 0 0 1 25 2 51 0 123 56 07EY 21 533 1927 32 504 191 8 487 2 51 181 2 511 179 32 441 0 0 0 1 25 2 51...

Page 7: ...10 477 1210 571 785 370 970 458 1160 547 750 354 925 436 1110 524 702 331 875 413 1055 498 655 309 825 389 1005 474 1035 488 1255 592 1460 689 RGRS 12ERAJS 11 x 10 279 x 245 3 4 559 LOW MED HIGH 1610...

Page 8: ...ters available through PROSTOCK RXGP F03 TWINNING KIT is for use with Rheem Value Series 90 Gas Furnaces for parallel operation requirements WARNING IMPORTANT NOTICE A SOLID METAL BASE PLATE SEE TABLE...

Page 9: ...Actual models may vary For detailed thermostat match up information see specification sheet form number T11 001 300 Series Deluxe Programmable 400 Series Special Applications Programmable 500 Series C...

Page 10: ...within the applicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contac...

Page 11: ...Air Notes RGRS RGRT Series 11...

Page 12: ...Smith Arkansas 72917 www rheem com In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice PRINTED IN U S A 05 12 QG FORM NO...

Reviews: