Model
Return Air Opening
Return Air Opening
Cabinet Size
Width (Inches)
Depth/Length (Inches)
17
15
7
⁄
8
19
3
⁄
4
21
19
3
⁄
8
19
3
⁄
4
24
22
7
⁄
8
19
3
⁄
4
MODEL
SIZE
(-)H1V
LIQUID
REFRIGERANT CONNECTIONS
SWEAT (IN.) [mm] ID
VAPOR
UNIT
HEIGHT
“H” IN
[mm]
SUPPLY
DUCT
“A” IN.
[mm]
LO
HI
UNIT WITH
COIL (MAX. kW.)
AIR FLOW
COIL (NOM) [L/s]
UNIT WEIGHT / SHIPPING
WEIGHT (LBS.) [kg]
UNIT
WIDTH
“W” IN
[mm]
2.3 DIMENSIONS & WEIGHTS (SEE FIGURE 3)
FIGURE 3
DIMENSIONS AND WEIGHTS -- SINGLE COIL UNITS
DIMENSIONAL DATA
A-1038-01
NOTE:
24" CLEARANCE REQUIRED
IN FRONT OF UNIT FOR FILTER
AND COIL MAINTENANCE.
ELECTRICAL CONNECTIONS
MAY EXIT TOP OR EITHER SIDE
HIGH VOLTAGE CONNECTION 7/8".
1 3/32", 1 31/32" DIA. KNOCK OUTS.
LOW VOLTAGE CONNECTION
5/8" AND 7/8" KNOCK OUT
(OUTSIDE OF CABINET)
AUXILIARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
HORIZONTAL APPLICATION ONLY
PRIMARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
AUXILIARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
UPFLOW/DOWNFLOW APPLICATION
ONLY
LIQUID LINE CONNECTION
COPPER (SWEAT)
VAPOR LINE CONNECTION
COPPER (SWEAT)
21
11
/
16
10
5
/
16
SUPPLY AIR
W
A
H
19
1
/
2
RETURN AIR
OPENING
UPFLOW UNIT SHOWN;
UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW.
HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.
RETURN AIR OPENING DIMENSIONS
7
MODEL
SIZE
(-)H2V
UNIT WIDTH
“W” IN. [mm]
UNIT HEIGHT
“H” IN. [mm]
MATCHED
TO
OUTDOOR UNIT
1
ODD*
ODD*
Normal
Normal
1
ST
STAGE
2
ND
STAGE
UNIT WITH COIL
(MAX. kW.)
NOMINAL COIL AIRFLOW [L/s]
UNIT WEIGHT / SHIPPING
WEIGHT (LBS.) [kg]
2421HT
21 [533]
42
1
/
2
[1080]
19
1
/
2
[495]
(-)ARL/(-)ASL-024JEC
500 [236]
600 [283]
650 [307]
775 [366]
99/117 [45/51]
3624HT
24
1
/
2
[622]
55
1
/
2
[1410]
23 [584]
(-)ASL-039JEC
725 [342]
825 [389]
975 [460]
1175 [555]
129/146 [59/66]
(-)ARL/(-)ASL-0935JEC
825 [389]
950 [448]
1000 [472]
1175 [555]
4824HT
24
1
/
2
[622]
55
1
/
2
[1410]
23 [584]
(-)ASL-048JEC
825 [389]
1000 [472] 1300 [614]
1600 [755]
143/160 [65/72]
(-)ARL-048JEC
1000 [472]
1200 [566] 1350 [637]
1600 [755]
6024HT
24
1
/
2
[622]
55
1
/
2
[1410]
23 [584]
(-)ASL-060JEC
925 [437]
1050 [496] 1325 [625]
1700 [802]
159/176 [72/80]
(-)ARL-060JEC
1025 [484]
1275 [602] 1400 [661]
1700 [802]
SUPPLY DUCT
“A” IN. [mm]
2417ST
3
/
8
" [9.53]
3
/
4
" [19.05]
17
1
/
2
" [445]
42
1
/
2
" [1080]
16" [409]
600 [283]
800 [378]
82/96 [37/44]
3617ST
3
/
8
" [9.53]
3
/
4
" [19.05]
17
1
/
2
" [445]
42
1
/
2
" [1080]
16" [409]
1000 [472]
1200 [566]
90/104 [41/47]
3621HT
3
/
8
" [9.53]
7
/
8
" [22.23]
21" [533]
57 [1448]
19
1
/
2
" [495]
1000 [472]
1200 [566]
135/147 [61/67]
3621MT
3
/
8
" [9.53]
7
/
8
" [22.23]
21" [533]
50
1
/
2
" [1282]
19
1
/
2
" [495]
1000 [472]
1200 [566]
126/142 [57/64]
4821MT
3
/
8
" [9.53]
7
/
8
" [22.23]
21" [533]
57 [1448]
19
1
/
2
" [495]
1400 [661]
1600 [755]
141/153 [64/69]
4821ST
3
/
8
" [9.53]
7
/
8
" [22.23]
21" [533]
50
1
/
2
" [1282]
19
1
/
2
" [495]
1400 [661]
1600 [755]
130/146 [59/66]
4824ST
3
/
8
" [9.53]
7
/
8
" [22.23]
24
1
/
2
" [622]
50
1
/
2
" [1282]
23" [585]
1600 [755]
—
142/160 [64/72]
6021HT
3
/
8
" [9.53]
7
/
8
" [22.23]
21" [533]
57 [1448]
19
1
/
2
" [495]
1600 [755]
1725 [814]
136/148 [62/67]
6024ST
3
/
8
" [9.53]
7
/
8
" [22.23]
24
1
/
2
" [622]
55
1
/
2
" [1410]
23" [585]
—
1800 [850]
162/179 [73/81]
Summary of Contents for RH1V2417STANJA
Page 54: ...54 FIGURE 44 COMFORT CONTROL2 SYSTEM AIR HANDLER WIRING DIAGRAM H2V...
Page 55: ...55...
Page 56: ...56 CM 0115...