92-102005-02-00
!
WARNING
DO NOT OPERATE THE FURNACE OR TANKLESS WATER HEATER WITHOUT THE SIDE WALL CAP IN PLACE AS
RECIRCULATION OF COMBUSTION PRODUCTS MAY OCCUR. WATER MAY ALSO COLLECT INSIDE THE COMBUS-
TION AIR PIPE AND FLOW TO THE BURNER ENCLOSURE. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN
PRODUCT DAMAGE OR IMPROPER OPERATION, PERSONAL INJURY OR DEATH.
!
WARNING
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE PERSONNEL FOR PROPER INSTALLA-
TION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE
ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE, POSSIBLY RESULTING IN FIRE, CARBON
MONOXIDE POISONING, EXPLOSION, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
!
WARNING
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP
IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICEMAN.
IMPORTANT:
The RXGY-G01 Vent Kit can be used for all above listed
furnace models. Refer to CondensingTankless water heater
manufacturer’s installation instructions for model exclusions!
KIT CONTENTS:
• Vent Cap
• Vent Plate
• 4- # 8 pan head screws 2” long” SMS
type A18-8 stainless steel.
• 4- #8 pan head screws 1” long , SMS
type A18-8 stainless steel.
THIS VENT KIT MUST BE INSTALLED BY A QUALIFIED SERVICE TECHNICIAN. CODES AND LOCAL UTILITY
REQUIREMENTS GOVERNING THE INSTALLATION OF GAS FIRED EQUIPMENT, WIRING, PLUMBING, AND FLUE
CONNECTIONS MUST BE ADHERED TO. IN THE ABSENCE OF LOCAL CODES, THE INSTALLATION MUST CONFORM
TO THE NATIONAL FUEL GAS CODE ANSI Z223.1 “LATEST EDITION,” OR CSA-B149 INSTALLATION CODES.
THE LATEST CODE MAY BE OBTAINED FROM CSA-INTERNATIONAL, 8501 EAST PLEASANT VALLEY ROAD,
CLEVELAND, OHIO 44131 OR CSA-INTERNATIONAL, 178 REXDALE BLVD., TORONTO, ONTARIO, CANADA M9W, 1R3
FOR USE WITH MODELS: R92PA, R95PA, R95TA, R96PA, R96VA & R98VA
MODEL RXGY - G01 (3”) (SP20286) SIDE WALL VENT KIT
FURNACE AND TANKLESS WATER HEATER
FURNACE ONLY
FOR FURNACE MODELS NOT LISTED SEE UNIT INSTALLATION INSTRUCTIONS OR 92-102340-01 FOUND ON RHEEMOTE.NET /PTS/RXGY
DIRECT VENT:
NON-DIRECT VENT:
This manual covers the installation of the RXGY-G01 side wall vent kit.
The RXGY-G01 is intended for:
Direct Venting:
Non-Direct Vent:
furnace and tankless water heaters
furnaces only