14
WATER SUPPLIES
This water heater must be installed in accordance with this advice to be covered by the warranty.
This water heater is manufactured to suit the water conditions of most public reticulated water supplies.
However, there are some known water chemistries which can have detrimental effects on the water heater
and its operation and / or life expectancy. If you are unsure of your water chemistry, you may be able to
obtain information from your local water supply authority. This water heater should only be connected to a
water supply which complies with these guidelines for the water heater warranty to apply.
CHANGE OF WATER SUPPLY
The changing or alternating from one water supply to another can have a detrimental effect on the operation
and / or life expectation of a water heater cylinder, a temperature pressure relief valve, a heating unit and a
solar collector in a direct solar water heater system.
Where there is a changeover from one water supply to another, e.g. a rainwater tank supply, bore water
supply, desalinated water supply, public reticulated water supply or water brought in from another supply,
then water chemistry information should be sought from the supplier or it should be tested to ensure the
water supply meets the requirements given in these guidelines for warranty to apply.
ANODE
The vitreous enamel lined cylinder of the water heater is only covered by warranty when the total dissolved
solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is
installed. The use of an incorrect colour coded anode will void the cylinder warranty and may shorten the life
of the water heater cylinder.
The correct colour coded anode must be selected and fitted to the water heater in accordance with the
following advice and the
Anode Selection chart
on page 14 for warranty to apply to the water heater cylinder.
Total Dissolved Solids
Anode colour code
0 – 40 mg/L
Green
40 – 150 mg/L
Green or Black
150 – 400 mg/L
Black
400 – 600 mg/L
Black or Blue
600 – 2500 mg/L
Blue
2500 mg/L +
Blue (no cylinder warranty)
The changing of anodes must be carried out by a plumber or authorised service person.
Note:
Some water analysis reports may state the conductivity of the water rather than the level of total
dissolved solids. Conductivity, measured in microsiemens per centimetre (
µ
S / cm), is directly proportional to
the TDS content of the water. TDS, in mg / L, is approximately 70% of the conductivity in
µ
S / cm.
CONDUCTIVITY -
µS/cm
TOTAL DISSOLVED SOLIDS & CONDUCTIVITY
(vitreous enamel lined water heater cylinder)
40
150
400
600
TOTAL DISSOLVED SOLIDS (TDS)
- mg/L
ANODE SELECTION
warranty applies to a vitreous enamel lined water heater cylinder if the
correct coloured anode is used for the TDS / conductivity level of water
2500
3570
no warranty
applies
to a vitreous
enamel lined
water heater
cylinder
Blue
Black
Green
60
215
570
860
0
0
Blue