WATER SUPPLIES
15
TOTAL DISSOLVED SOLIDS
The stainless steel cylinder of the water heater is only covered by the Rheem
warranty when the total dissolved solids (TDS) content in the water is less than
600 mg / L.
Note:
Some water analysis reports may state the conductivity of the water
rather than the level of total dissolved solids. Conductivity, measured in
microsiemens per centimetre (
µ
S / cm), is directly proportional to the TDS
content of the water. TDS, in mg / L, is approximately 70% of the conductivity in
µ
S / cm.
SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY
The water heater and its components are not suitable for certain water
chemistries. Those chemistries are listed below. If the water heater is
connected at any time to a water supply with the following water chemistry, the
Rheem warranty will not cover any resultant faults on the components listed
below:
Water Chemistry
Component
Chloride > 250 mg / L
water heater cylinder
pH < 6.0 or > 9.5
water heater cylinder
Total Dissolved Solids (TDS) > 600 mg / L
water heater cylinder
Saturation Index (SI) < -1.0
copper sheathed heating unit
Saturation Index (SI) > +0.4
(if expansion control valve is not fitted)
water heater cylinder
temperature pressure relief valve
Saturation Index (SI) > +0.8
water heater cylinder
standard watts density heating unit
Magnesium > 10 mg / L
water heater cylinder
Iron > 1 mg / L
water heater cylinder
Sodium > 150 mg / L
water heater cylinder