Fault Finding Chart 6
6
Is the
temperature
at the hot tap similar
to the thermostat
setting?
Water too hot
Explain to customer the reasons for storing
water hotter than they may desire i.e.
1. When mixed with cold water more hot
water delivery is possible
2. Prohibit bacteria growth
Tempering devices should be suggested as
a solution
YES
Is the
thermostat in
good contact
with the
cylinder?
Remove the thermostat and clean any
scale from the cylinder wall.
Re-tension bracket and refit thermostat
NO
Are the
ECO contacts
closed?
Is the
element installed
in the correct
orientation?
YES
Replace thermostat
NO
Refit element correctly
NO
Replace thermostat
YES
Reset the ECO
Bottom thermostat - Test 5
Top thermostat - Test 10
Are the
thermostat contacts
closed?
YES
Bottom thermostat - Test 6
Top thermostat - Tests 11 & 12
NO
YES
Is
a tempering valve
fitted?
NO
NO
3.1
YES
Is
the model a Rheem
Plus?
YES
3.2
NO