background image

RHG Products Company 

 

 
 

 

 
 

 

 

RHG 3 & 4 Stage Water Powered 

H2PRO 

 User Manual 

Summary of Contents for H2PRO

Page 1: ...RHG Products Company RHG 3 4 Stage Water Powered H2PRO User Manual ...

Page 2: ...RHG Products Company ...

Page 3: ...ect for any damage that may have occurred during shipping 2 Be sure to inventory all items that were to be included with your order 3 Any damage or missing components must be reported within 24 hours to the supplier of your system 4 Your H2PRO is shipped complete in 1 box ...

Page 4: ...nitial set up and when you change your carbon filter 6 As water begins to flow out of the bypass valve blue valve below the inlets and outlet slowly close the bypass valve all the way Although the valve is fully closed water will still flow out of it This is normal 7 It will take a few minutes for all of the air to purge out of your system before water makes its way out of the reel 8 After the ini...

Page 5: ... acceptable purity in RO Only Mode for your application switch to DI mode by closing the 1 2 grey valve labeled R O and opening the 1 2 grey valve labeled D I Water will flow from different outlets depending on which valve you have open ALWAYS BE SURE ONE GREY VALVE IS OPEN DURING PRODUCTION TDS CREEP PREVENT TDS CREEP AND EXTEND DI LIFE For a few moments after RO membranes begin production they f...

Page 6: ...longer than 2 weeks close your DI valve and open your RO only valve Run the RO in flush mode for 4 minutes and RO production mode for 10 minutes before reconnecting the DI cartridge check RO efficiency at this time 3 Turn off the water supply to the unit 4 Disconnect the water supply It is important to always flush the system after each use Failure to do so will decrease the filters life ...

Page 7: ...carbon sediment cartridge needs to be replaced every 6 months to protect the RO membranes Failure to do so will void your warranty The job of the carbon filter is to remove the chlorine It is possible to check to see if your carbon filter is still working efficiently with a chlorine test kit Your H2PRO system is a water purification system and as such it needs to be maintained Running water throug...

Page 8: ...s installed There is an o ring on the filter This o ring should go at the top end of the housing Insert the filter from the opposite end first Be sure to run water through the system without any booster motor pump assembly powered on to purge all air out of the system before or you risk damaging the filters Reassemble filter housing and reconnect hoses You may need to relubricate your filter housi...

Page 9: ...RHG Products Company ...

Page 10: ...RHG Products Company ...

Page 11: ...er coming from the water supply If your pressure is below 50 PSI you will want to consider a booster pump to increase the pressure coming into the system If you are not getting adequate flow at the brush of your waterfed pole check your pressure gauge to see that your incoming PSI is 50 or higher If it is you may have a blockage elsewhere in your set up Any alterations to your system will void its...