RHG Products Company
Operation Instructions
First time use:
1.
Remove the plug from the outlet of your carbon pre-filter and
follow the instructions. (Flush your carbon filter). THIS IS
EXTREMELY IMPORTANT.
2.
Attach a garden hose to the inlet of your system. (located on
the side of the system above the waste valve)
3.
Attach a hose (pole hose or hose reel) to the desired outlet of
your system. (located on the side of the system above the inlet)
4.
Turn tap water supply on. Start your system with the bypass
valve fully open.
5.
After flushing the carbon connect the black tube that is coming
up from the RO to the outlet elbow of the carbon filter. (you only
have to flush the carbon filter on initial set up and when you
change your carbon filter)
6.
As water begins to flow out of the bypass valve (blue valve
below the inlets and outlet), slowly close the bypass valve all the
way. Although the valve is fully closed, water will still flow out
of it. This is normal.
7.
It will take a few minutes for all of the air to purge out of your
system before water makes its way out of the reel.
8.
After the initial ‘air purge’ you will not need to purge air again
unless you replace a filter.
9.
You are now fully operational.
Every day use:
1.
Attach your tap water supply as you did on set up.
2.
Turn tap water supply on. Always start your system with the
bypass valve fully open.
3.
Allow system to flush for a few moments before beginning
production.
4.
Attach cleaning equipment to system and close bypass valve to
begin production. It is recommended that you follow the TDS
CREEP instructions below.